My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2021 4:13:52 PM
Creation date
6/11/2020 10:35:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM ( Pagel of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test 9 36 Month Test <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10180643 1 8/8 /2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Quik Stop # 125 <br /> Business Site Address City ZIP Code <br /> 1580 W. Main St Ripon 95366 <br /> il . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) Phone # <br /> Juan Jauregui ( 916 ) 372 - 1888 <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 617238 5246964 8/30/2019 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID : (By tank number, stored product, etc.) A Gasoline - 87 B Gasoline - 91 C Diesel D <br /> Tank Containment <br /> Tightness Test Result O Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA N Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA O Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail R NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Turbine / Product Piping Sump <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑ Pass ❑ Fail p NA ❑ Pass ❑ Fail p NA ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail ❑ NA <br /> VENT / TRANSITION SUMP ID : a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass [I Fail ❑ NA <br /> UDC ID : 1 Disp # 1 -2 2 Disp #3-4 3 Disp #5-6 4 <br /> Tightness Test Result El Pass ❑ Fail ❑ NA O Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 5 16 7 8 <br /> Tightness Test Result ElPass ❑ Fail E] NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> All items marked "Fail' or `NA " must be explained in their respective "COMMENTS" section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, Title 23 , Division <br /> 3 , Chapter 16, Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, & Identification, UST = Underground Storage Tank, ICC = International Code Council, NA = Not Applicable, UDC = Under- <br /> Dispenser Containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.