My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
14900
>
2200 - Hazardous Waste Program
>
PR0545439
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:46:01 PM
Creation date
6/11/2020 11:43:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0545439
PE
2220
FACILITY_ID
FA0009464
FACILITY_NAME
TOWER PARK RESORT/MARINA
STREET_NUMBER
14900
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05503015
CURRENT_STATUS
01
SITE_LOCATION
14900 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J 0 A Q I I I Irl Environmental Health Department <br /> C o u N T AMENDED <br /> 4/15/2020 <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TOWER PARK RESORT/MARINA 14900 W HWY 12 , LODI February 25, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> practicable time if the existing detection technology or site conditions will not allow detection of a release within 24 <br /> hours. <br /> Title 22 California Code of Regulations section 66265.193(f) <br /> (f)Ancillary equipment shall be provided with full secondary containment(e.g., trench,jacketing, double-walled <br /> piping)that meets the requirements of subsections(b)and (c)of this section except for: <br /> (1)aboveground piping (exclusive of flanges,joints, valves, and connections)that are visually inspected for leaks on <br /> a daily basis; <br /> (2)welded flanges,welded joints, and welded connections that are visually inspected for leaks on a daily basis; <br /> (3)sealless or magnetic coupling pumps and sealless valves,that are visually inspected for leaks on a daily basis; <br /> and <br /> (4)pressurized aboveground piping systems with automatic shut-off devices(e.g., excess flow check valves,flow <br /> metering shutdown devices, loss of pressure actuated shut-off devices)that are visually inspected for leaks on a <br /> daily basis. <br /> CORRECTIVE ACTION: Have a qualified Professional Engineer prepare a tank assessment for the 290 gallon <br /> used oil tank. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. Provide a copy of the tank assessment,when available. <br /> This is a Class I violation. <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATION: The facility has a 290 gallon used oil hazardous waste tank. Three years of complete daily tank <br /> inspection records were not observed during the inspection. <br /> REGULATION GUIDANCE: <br /> (a)The owner or operator shall inspect,where present, at least once each operating day: <br /> (1)overfill/spill control equipment(e.g.,waste-feed cutoff systems, bypass systems, and drainage systems)to <br /> ensure that it is in good working order; <br /> (2)the aboveground portions of the tank system, if any, to detect corrosion or releases of waste; <br /> (3)data gathered from monitoring equipment and leak-detection equipment, (e.g., pressure and temperature <br /> gauges, monitoring wells)to ensure that the tank system is being operated according to its design; <br /> (4)the construction materials and the area immediately surrounding the externally accessible portion of the tank <br /> system including secondary containment structures(e.g., dikes)to detect erosion or signs of releases of hazardous <br /> waste (e.g.,wet spots, dead vegetation); and <br /> (5)for uncovered tanks,the level of waste in the tank, to ensure compliance with section 66265.194(b)(3). <br /> (c)The owner or operator shall document in the operating record of the facility an inspection of those items in <br /> subsection (a)of this section. <br /> CORRECTIVE ACTION: Immediately start conducting and documenting complete daily hazardous waste tank <br /> inspections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a Class 11 violation. <br /> FA0009464 PR0545439 SCO01 02/25/2020 <br /> EHD 22-02 Rev.9/20/2019 Page 12 of 15 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.