My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
14900
>
2200 - Hazardous Waste Program
>
PR0545439
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:46:01 PM
Creation date
6/11/2020 11:43:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0545439
PE
2220
FACILITY_ID
FA0009464
FACILITY_NAME
TOWER PARK RESORT/MARINA
STREET_NUMBER
14900
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05503015
CURRENT_STATUS
01
SITE_LOCATION
14900 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> AMENDED <br /> 2/27/2020 <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TOWER PARK RESORT/MARINA 14900 W HWY 12 , LODI February 25, 2020 <br /> Labeling and Storage <br /> 610 CCR 66262.34(b)(1) Stored acutely or extremely hazardous waste onsite greater than 90 days V R c;COS <br /> 611 HSC 25200.3.1(b) Failure of laboratory to comply with hazardous waste accumulation area requirements =V R :_:COS <br /> Universal Waste <br /> 701 CCR 66273.32(a) UW handler failed to notify EPA RA and obtain an EPA ID#prior to accumulating>5000kg of UW V c R COS <br /> 702 CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW ❑V u R n COS <br /> 703 CCR 66273.33(a) UW handier failed to store UW batteries in a manner that prevents release to the environment n V n R c:;COS <br /> 704 CCR 66273.33(b) UW handler failed to properly manage universal waste lamps o V o R r;COS <br /> 705 CCR 66273.33(c) UW handler failed to properly manage mercury containing universal waste u V n R n COS <br /> 706 CCR 66273.33.5 UW handler failed to prevent release of universal waste electronic devices,CRTs or CRT glass u V n R i COS <br /> 707 HSC 25201.16(e) Failed to manage aerosol cans in a manner that prevents the unauthorized release of waste n V n R ❑COS <br /> 708 HSC 25201.16(f) Failed to properly manage containers of waste aerosol cans n V n R n COS <br /> 709 HSC 25201.16(g) Failed to store used aerosol cans in an accumulation container n V o R c COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing u V u R u COS <br /> 711 HSC 25201.160) Failed to submit or amend notification for aerosol can processing n V n R u COS <br /> 712 CCR 66273.34 UW handler(UWH)failed to label universal waste to identify type of universal waste n V n R u COS <br /> 713 CCR 66273.35 UWH stored UW onsite greater than one year or was unable to demonstrate storage time n V ❑R ❑COS <br /> 714 CCR 66273.36 UWH failed to train employees and maintain records on UW handling and emergency procedures ❑V n R o COS <br /> 715 CCR 66273.39 UWH failed to keep complete records of each shipment of universal waste for three years n V o R o COS <br /> 716 CCR 66273.40(a)(3)(4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification n V c,,R o COS <br /> 717 CCR 66273.32(b) UWH failed to obtain an ID number from DTSC prior to accumulating>5000kg of non-RCRA UW n V ❑R u COS <br /> 718 CCR 66273.32(d) Failure of a UW handler to submit a complete annual report to DTSC n V n R n COS <br /> 719 CCR 66273.38 Failure of UW handler to transfer UW to the appropriate destination facility n V n R n COS <br /> 720 CCR 66273.31(a) UW handler caused improper disposal of UW n V n R n COS <br /> 721 CCR 66273.8(b) Conditionally exempt small quantity UW generator caused improper disposal of UW r:V :_i R a COS <br /> Appliance Recycler <br /> 801 HSC 25211.4 Failure to obtain Certified Appliance Recycler certification(CAR) o V u R n COS <br /> 802 HSC 25211.2,25211.3 Failure of a CAR to provide docs that materials that require special handling have been removed a V n R n COS <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling V n R n COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation o V n R n COS <br /> 3020 See below Unlisted Training violation o V a R n COS <br /> 3030 See below Unlisted Operations/Maintenance violation o V u R u COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ❑V o R u COS <br /> 3050 See below Unlisted Abandon ment/lIlegaI Disposal/Unauthorized Treatment violation n V ri R n COS <br /> FA0009464 PRO545439 SCO01 02/25/2020 <br /> EHD 22-01 Rev.9/20/2019 Page 3 of 8 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.