Laserfiche WebLink
UNDERGROUNDSTORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT IN 3PECTION REPORT FORM ( Page 1 of i ) <br /> Type of Action ❑ Installation Inspection ❑ Re 3air Inspection x❑ 36 Month Inspection <br /> I . FACILITY I qFORMATION <br /> CERS ID <br /> 10181439 Date of Overfill Prevention Equipment Inspection <br /> 4/4/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> AG SPANOS JET CENTER <br /> Business Site Address City ZIP Code <br /> 4800 S AIRPORT WAY STOCKTON 95206 <br /> II . UNDERGROUND STORAGE TANK ORVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Felix Ramirez (209 ) 744 - 0112 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 08 - 1740 Ex . 03/31 /2020 88830 2I UT 11 /9/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> FF- FF- EBW , Phil -Tite & EVR Phase 1 1009883708 EX 11 29 -20 OPW 104- 634 Ex 3- 14-2020 <br /> Emco 3147 Ex . 11 - 16- 20 VR : B34976 ATG : 7/7/20 Incon 1009883708 Ex 11 -30-20 <br /> III . OVERFILL PREVENTION EQUIP ENT INSPECTION INFORMATION <br /> Inspection Method 0 Manufacturer Guidelines (Specify) : <br /> Used : EMCO <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify) : <br /> Attach the inspection procedures and all documentation required o determine the results. # of Attached Pages 5 <br /> TANK ID : (By tank number, stored product, etc.) JET A JET A JET A <br /> What is the tank inside diameter? (Inches) 127 120 92 <br /> Is the fill piping secondarily contained ? ❑ Yes ❑x No Yes ❑x No ❑ Yes ❑x No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained ? ❑ Yes [E No Yes 2 No ❑ Yes 0 No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) EMCO EMCO EMCO <br /> A1100 A1100 A11o0 <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow x Shuts Off Flow ❑x Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) ❑ Restricts Flow Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> ❑ AIV Alarm AIV Alarm ❑ AIV Alarm ❑ A/V Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes ❑x No Yes 0 No ❑ Yes [jg No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 1 1 6 107 85 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 95 % 94% 96% <br /> Is the overfill prevention in proper operating condition ❑x Yes Yes ❑ Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V.) No (Specify in V.) ❑x No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INS ECTION RESULTS <br /> Overfill Prevention Inspection Results ❑x Pass ❑ Fail Pass ❑ Fail ❑ Pass ® Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail' must be explained in this section. Any addition I comments may also be provided here. <br /> 12000 GALLON TANK NOT SET AT 95 % <br /> VI . CERTIFICATION BY UST SERVICE TECH 41CIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected n accordance with California Code of Regulations , Title 23 , <br /> Division 3, Chapter 16, Section 2637 . 2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification , UST = Underground Sto age Tank, ICC = International Code Council, AIV = Audible and Visual <br />