Laserfiche WebLink
2 q 5 <br /> MATERIAL FOR DEEP WELL ANODES <br /> /'(r/f}�ER ,TIL SEAL ITEM OUANT DESCRIPTION CODE NO <br /> •� 1f 1 � I 2 ANODES 3"XB4'DURICHLOR 5i TYPE TA-3 WITH 56-9353 <br /> 125' "8 HMwPE WIRE <br /> VALVE FRAME , V2 p 6UbLB5 COKE BREEZE BACKFILL 25 OHM-CM OR LESS 56-9086 <br /> n & COVER <br /> 1 9 10 SEE NOTE 1 3 SREWD WIRE 110 AWG RHW&N OR HMWPE 29-4376 <br /> E CONDUIT TO POLE MOUNTED OR- 4 8 PIPE CLAMPS & CENTERING GUIDE <br /> .I, E LNVERGROUND RECTIFIER, (SEE GS 0-II.I1. 5 1 1-I/4" ABS PLASTIC I80' TURN <br /> ' -__�" WRAP UNDERGROUND PORTION OF CONOU!T 36-0469 <br /> WITH PLASTIC TAPE IF CONDUIT 1S METALLIC. 6 144' I i/4" A65 PLASTIC DUCT TYPE DB <br /> s� R 3 7 1 1-1/4" TEMP PLASTIC CAP <br /> E <br /> B 30 PLASTIC TIE LOCKS <br /> �~ ��SEAL END OF CONDUIT WITH TAC-TAPE 9A I VALVE FRAME <br /> 6 CODE 50-7036. IAOiJA SEAL, CODE 50-7030 g8 I 12' EXTENSION SEE GAS STD K40-K40.1 <br /> m MAY OF USED, BUT TAC-TAPE 9C I VALVE BOX COYER <br /> IS PREFERRED FOR GAS DEPARTMENT USE} <br /> 10 1 TEST LEAD BOX, SEE GAS STD 0-10.1 <br /> I I t 1 AS 11E0'0 CONCRETE <br /> A' 12 I SPLICE, ANODE WIRE" SEE GAS STD 0-12 <br /> .' SEE NOTE H 3/16 <br /> WELDING ROD <br /> s.I <br /> is <br /> D CENTERING <br /> DEVICE <br /> FOR INSTALLATION PROCEDURE NOTES' <br /> FI___-02 SEE NOTE D/W ANODE D/W ANODE <br /> ' A. DRILL A 10' DIAMETER HOLE 120 FT DEEP AT CHOSEN LOCATION. <br /> 8 SEE NOTE C R. ASSEMBLE ANODES AND i-1/4'DUCT 0.S SHOWN OBSERVE SPACING. <br /> m C. TAPE OR STRAP ANODE WIRE TO THE OUTSIDE OF THE VENT PIPE EVERY 4'. <br /> • I BEND <br /> D NOTIFY THE PRESEONT. ARE TO <br /> . M E. WHEN USING MUG TO SUPPORT THE WALLS OF THE HOLE. THIN MUD OUT WITH <br /> E� <br /> CONDU3T CLEAR WATER PR10R 10 INSTALLING COKE BREEZE. <br /> 1 <br /> 1 F. LOWER'ASSEMBLED ANODE STRING AND 1-i/('DUCT INTO HOLE USING SUITABLE LINE. <br /> _ CLAMP, CHAIN LINK UNTIL CONTACT WITH BOTTOM IS MADE. BE CAREFUL WITH ANODE LEAD WIRES. <br /> FENCE, SIZED TO G. HOLD ANODES.IN POSITION AND KEEP WIRES TAUT WHILE POURING IN 600 LBS. <br /> /� FIT ANODE OF COKEkSREEZE. MEASURE DEPTH TO TOP OF COKE BREEZE. TCP OF COKE <br /> ,oya ANODE GLIDE CA4 BE EITHER BREEZE'COLl1MN SHALL BE 90 FEET FROM SURFACE. ADD COKE BREEZE <br /> WELDED TO CLAMP' OR CLAMPED AS REOUIREO. <br /> TO ANODE AND BENT TO SHAPE H. SILL HOLE.WITH CONCRETE (CLASS B MIX-5 SACKS OF PORTLAND CEMENT PER <br /> (DEEP WELLm) ANODE CENTERING DEVICE CUBIC YARDI. <br /> DETAIL "A N 1. SEE GAS STANDARD 0-10.1 FOR TEST LEAD BOX OPTIONS. <br /> LOCATE NEAR BASE OF POWER POLE. WIRES MAY <br /> ALSO BE SPLICED INSIDE UNDERGROUND RECTIFIER CONCRETE BOX IGS 0-ILEI. <br /> N <br /> J. ALL ORK <br /> R RZSOURCES <br /> BULLETIN,SWATER BWELLS E&I CATHODIC APROTECTION NCE WITH EWELLS F(SEC E13100-13806 <br /> A) / CALIF. WATER CODE). - <br /> -'-- L <br /> wl NOTES <br /> q I �I Il J j1. SLOTS FOR VENTILATION OF CHLORINE GAS SHALL BE INSERTED IN(`J} tj THE LOWER 30' OF THE 1-1/4" ABS DUCT. EACH SLOT SHALL BE <br /> N ROTATED 90° FROM THE PREVIOUS SLOT. CUT SLOT W/CIRCULAR SAW. <br /> B — 1 2"XI/16" SLOT <br /> (SEE NOTE 1) L° <br /> TYPICAL <br /> SEE DETAIL 'E' 10'. <br /> VENTILATION SLOTS CENTERING GUILE <br /> DETAIL "g„ �Eo <br /> • �Tl4t�i A <br /> ,� MIG710F IL>t 1 <br /> r BiLL a H"L <br /> e rJ- REVISED DETAIL A 6995 l.flV.S/p:/S 9Y PIPING-DATA SHEET DW LIST <br /> REVISED TO 176'. ,RANGED TITLE, M S"PY. r <br /> A NODE. SPLICE i CENTERING GUIDE • [lS5TALLATION OF ANODES SUPSDS N <br /> 6 9-12-7 REVISED DEPT" MLASUREKNTS RP NA RTA PAL MIR MRD STEPNAN ! 120' DEEP wPw BY <br /> 5 T-Ie-`8 REVISED N07FS, CMGED DEPTH AA xE RTA PAi JAF C"MD SHEET NG. SHEETS <br /> >tEASURFNEkiS �' GAS STANDARD <br /> 283835 <br /> «o, Banc DEscalvrtaN ays�Lc on. cnn.swr. ww. eT P►L SCALES T7 'DACIFlC GAS AND ELECTRIC COMPANY Q <br /> CADD e11069 09!71/eY pEV33l0„5 CT <br /> $AEI FRANCIS[0,LAL 1i0RNiA D <br /> u-<sr i..e.nnR.tco m o,w.��•r 4u t.r E 1 <br /> d, � <br />