Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST)monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10180717 5/28/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) Building# <br /> CHEVRON <br /> Business Site Address City ZIP Code <br /> 10878 N HWY 99 � STOCKTON <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> Nucleus Pump Services (916) 382-4761 <br /> Mailing Address <br /> 601 1st Ave, Suite B, Sacramento, CA 95818 <br /> Name of UST Service Technician Performing the Certification(Print as shown on the/CC Certification) <br /> Chris Bishop <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 949066 8216429 3/4/2022 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> VEEDER ROOT B36744 5-6-2021 <br /> III. RESULTS OF TESTING /SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> Monitoring System Set-up Alarm History Report <br /> Was any monitoring equipment replaced? ❑ N El <br /> (If"Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage, debris, or liquid found inside any secondary containment systems? El El <br /> (If"Yes,"describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? [K El El <br /> (If"No,"describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section,describe how and when the issues were or will be corrected. <br /> REMOVED ABOUT FOUR CUPS OF WATER FROM THE 91-2 STP SUMP AND ABOUT TWO CUPS <br /> FROM THE DIESEL STP SUMP. DISPENSER 3-4 ,91 THE CHAIN HAD TO BE ADJUSTED. <br /> DISPENSER 5-6 ,87 THE CHAIN HAD TO BE ADJUSTED. DISPENSER 7/8 ,91 THE CLIP FOR THE <br /> CHAIN HAD COME LOSE REINSTALLED THE CLIP AND MADE ADJUSTMENTS.ALL OTHER <br /> FLOATS AND CHAINS WORKING CORRECTLY. <br /> RECA1`1 <br /> O <br /> JUN 10 2020 <br /> ENVIRONMENTAL HEALTH <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations,Title 23, Division 3,Chapter 16,Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g., manufacturers' checklists, monitoring system set-up, alarm history report,etc.) necessary <br /> to verify that this information and the site plag showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System,ID=Identification,ICC=International Code Council,Y=Yes,N=No,NA=Not Applicable <br />