Laserfiche WebLink
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Colonial Energy CE 40138 (DBA Power Mart) 1 14000 E HWY 88 , LOCKEFORD April 08, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> OBSERVATION: The 91 product line leak detector was replaced on 4/10/2019, FE Petro leak detector was replaced <br /> with a VMI leak detector which was not a "like for like" replacement and a permit was not obtained from the EHD. <br /> REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed, trained, and certified contractor pursuant to the EHD's policy and a permit <br /> obtained within one business day from the EHD. All other repairs must have a permit submitted to and approved by <br /> the EHD prior to beginning work. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD for the replacement of the 91 product line leak <br /> detector(4/10/19) . A"Failure to Obtain a Permit" penalty applies. <br /> This is a minor violation. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> OBSERVATION: Seepage was detected below the shear valve in under dispenser containment (UDC) 1/2 and 3/4 , <br /> indicating a leak in the primary containment. <br /> REGULATION GUIDANCE: All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the <br /> failed component(s), under permit and inspection of the EHD if necessary. <br /> This is a minor violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> OBSERVATION: Liquid was observed in the diesel, 91, and 87 turbine sumps. <br /> REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. <br /> CORRECTIVE ACTION: The service technician removed approximately two gallons of liquid from the diesel, 91 and <br /> 87 turbine sumps. Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This was corrected on site. <br /> This is a minor violation. <br /> FA0000091 PR0231631 SCO01 04/08/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />