Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> L■ COUNTY <br /> ^ r1 `p' Greorne5S grows here, Time In: 10.10 am <br /> Time Out: 11:00 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: DAYS INN AND SUITES Date: 06/05/2020 <br /> Address: 710 S CHEROKEE LN, LODI 95240 <br /> Owner/Operator: VINA YAK HOLDINGS LLC Telephone: (209)369-8484 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:Diarrhea Sign is not posted at the entrance area of the pool.The pool operator shall post at the entrance <br /> area of a public pool, a sign in letters at least 1 inch (25 mm)high, that clearly states that persons with diarrhea and persons <br /> who have had diarrhea within the prior 14 days shall not enter the pool water. Correct within one week. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #6 Hose Bibb Anti Siphon Device <br /> OBSERVATIONS:There is no backflow device installed for the makeup water flow control. Provide atmospheric vacuum <br /> breaker or equivalent within one month. <br /> CALCODE DESCRIPTION:Hose bibbs shall be protected by a non-removable backflow preventer or atmospheric pressure break installed <br /> in accordance with Uniform Plumbing Code. (CBC 31188) <br /> #7 Pool Deck <br /> OBSERVATIONS:There are gaps between pool coping and concrete floor. Seal these gaps within one month. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 3114B)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The South side Handrails are loose. Secure or tighten this handrail within one month. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> FA0000495 PR0360122 SCO01 06/05/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />