: SA NUJ FAQ U I N Environmental Health Department <br /> ._ COUNTY <br /> Tl <br /> E"r : <br /> ^'•ti7F Opt�� Timee OOutut: 122:0Greotness grows here. 1 :00 am <br /> 0 pm <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: STOCKTON GOLF&COUNTRY CLUB Date: 06/10/2020 <br /> Address: 3800 W COUNTRY CLUB BLVD, STOCKTON 95204 <br /> Owner/Operator: STOCKTON GOLF&COUNTRY CLUB Telephone: (209)466-4313 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:No Life Guard on Duty sign is not posted. Post before pool opens to members. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #4 Safety Equipment <br /> OBSERVATIONS:Life ring is in life guard room. Place it in pool area before pool reopens. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained,readily visible,and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Four out of 5 lights are not working. Replace lights by 2 weeks. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:Filter#1 leaks. Make necessary repairs by 2 weeks. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 3125B)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br /> FA0002327 PR0360453 SCO01 06/10/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />