Laserfiche WebLink
Di Salvo Truck Lines-SM <br /> March 9. IM <br /> Page-8- <br /> approximately 10 inches bgs to at least 16 feet bgs consisted of generally dark gray to moderately <br /> yellowish brown, organic clay. Approximatley 5% to 20% very fine sand was present from a depth of 8 <br /> feet to 16 feet bgs in SPI and SP2 Iocated east of the former tank locations. Trace amounts of very fine <br /> sand were present from 4 feet to 9 feet bgs in SP3 located north of the former tank locations. <br /> Laboratory analyses of soil samples SP2-6 and SP2-12 detected TEX constituents at concentrations <br /> ranging from 150 ug/kg to 320 µg/kg and diesel at concentrations ranging from 1,600 mg/l:g to 5,800 <br /> mg/kg. Diesel was detected in SP3-6, SP3-12, SP4-6 and SP4-12 at concentrations ranging from 5.8 <br /> mg/kg to 16 mg/kg. Benzene, kerosene and motor oil were not dctected in SP2-6 and SP2-12 at or above <br /> the reported laboratory detection limits. BTEX constituents, kerosene and motor oil were not detected at <br /> or above the reported laboratory detection limits in the soil samples collected from SP3 and SP4. No <br /> evidence of hydrocarbon contamination was detected at or above the reported laboratory detection limits in <br /> the soil samples collected from SP1. The reported laboratory detection limits for BTEX constituents and <br /> TEPH were raised in SP2 because of high hydrocarbon concentrations detected in the soil samples <br /> collected from SP2. <br /> A moderate petroleum odor was noted in SP2-6 and SP2-12 and PID readings of SP2-6 and SP2- <br /> 12 ranged from 60 ppm to 80 ppm, respectively. A slight petroleum odor was noted in SP4-I2 and the <br /> PID indicated 1 ppm hydrocarbon gases. No hydrocarbon odors or PID readings were noted in core <br /> samples collected from immediately above the capillary zone in SPI, SP3 and SP4 or in the core samples <br /> collected from the capillary zone in SPI and SP3. <br /> The rate of groundwater recharge into each soil probe was very slow. Groundwater samples were <br /> collected from SP1, SP2, and SP4; however, SP3 did not effectively recharge and a groundwater sample <br /> was not collected. Laboratory analyses: of groundwater samples collected from SP2 and SP4 detected <br /> BTEX constituents at concentrations ranging from ND to 5.0 µg/1 and diesel at concentrations ranging <br /> from 350 mg/l to 520 mg/1. A sheen was noted on the groundwater samples collected from SP2 and SP4. <br /> Diesel was detected in SPI at a concentration of 18 mg/l. A sheen was not noted on the groundwater <br /> samples collected from SPI or in the trace amount of groundwater purged from SP3. The Iaboratory <br /> detection limits requested by SJCPHS,EHD, on the day of field work, were raised because of elevated <br /> hydrocarbon concentrations in the groundwater samples. Kerosene and motor oil were not detected at or <br /> LJ CONDOR <br />