Laserfiche WebLink
Waste Evaluation &Testing Summary <br /> Metal Wastes from Cutting and Grinding(Sample from RTS Packaging-Stockton,CA) <br /> TTLC(ppm) STLC(ppm) TCLP(ppm) <br /> Compound/Substances EPA Waste codes Regulatory Regulatory 3 Regulatory <br /> Result Result <br /> Level' Level t Result Level <br /> Antimony None/CA Only <40 500 not required 15 NA <br /> Arsenic D004 <40 500 not required 5 <0.10 5 <br /> Barium D005 <10 10,000 not required 100 0.195 100 <br /> Beryllium None/CA Only <4 75 not required 0.75 NA <br /> Cadmium D006 <10 100 not required 1 <0.10 1 <br /> Chromium and/or chromium(III)compounds D007 800 2,500 not required 5 <0.10 5 <br /> Chromium(VI)compounds D007 NT 500 not required 5 NT <br /> Cobalt None/CA Only 63 8,000 not required 80 NA <br /> Copper None/CA Only 1630 2,500 not required 25 NA <br /> Lead D008 35.2 1,000 not required 5 <0.10 5 <br /> Mercury D009 <0.03 20 not required 0.2 <0.01 0.2 <br /> Molybdenum and/or molybdenum compounds None/CA Only 165 3,500 not required 350 NA <br /> Nickel and/or nickel compounds None/CA Only 707 2,000 not required 20 NA <br /> Selenium D010 <40 100 not required 1 <0.10 1 <br /> Silver D011 <20 500 not required 5 <0.10 5 <br /> Thallium and/or thallium compounds None/CA Only <40 700 not required 7 NA <br /> Vanadium and/or vanadium compounds None/CA Only 133 2,400 not required 24 NA <br /> Zinc None/CA Only 100 5,000 not required 250 NA <br /> Note 1:22 CCR§66261.24 <br /> Note 2:Pace Analytical Sample Results,L1122870,METAL FILINGS 07232019,8/1/19 <br /> Note 3:Pace Analytical Sample Results,L1125610,METAL FILINGS 072320,8/9/19 <br /> NT=not tested;NA=Not Applicable <br />