Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SPILL CONTAINER TESTING REPORT FORM ( Page 1 of 1 ) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑Q 12 Month Test <br /> I . FACILITY INFORMATION <br /> D <br /> CERS ID ate of Spill Container Test <br /> 10594654 1 /21 /2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> CRM - PACIFIC AVE CHEVRON <br /> Business Site Address City ZIP Code <br /> 6633 PACIFIC AVE STOCKTON , CA 95207 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification.) Phone # <br /> DAVID WINKLER 1 (209 ) 744-0112 <br /> Contractor i Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 0 & 1739 Ex . 3/31 /20 8883059- UT 1 /29/2020 <br /> Spill Container Testing Training and Certifications (List applicable certifications.) <br /> Franklin Fueling - EBW & Phil Tite # 10009853708 Ex. 11 /29/20 <br /> OPW # 104-633 Ex. 3/14/2020 <br /> III . SPILL CONTAINER TESTING INFORMATION <br /> Test Method Used : ❑x Manufacturer Guidelines (Specify) : WATER TEST <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the testing procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) 87 91 DSL <br /> Spill Container Manufacturer: PT PT PT <br /> Method of Cathodic Protection: ❑x Non-Metallic ❑x Non-Metallic I] Non-Metallic ❑ Non-Metallic <br /> ❑ Isolation ❑ Isolation ❑ Isolation ❑ Isolation <br /> ❑ Other (Specify in V) ❑ Other (Specify in V.) ❑ Other (Specify in V.) ❑ Other (Specify in V.) <br /> Inside Diameter of Spill Container: (Inches) 12 12 12 <br /> Depth of Spill Container: (inches) 13 13 131 /2 <br /> Does the spill container have a 5 gallon capacity? 0 Yes ❑ No 0 Yes ❑ No ❑x Yes ❑ No ❑ Yes ❑ No <br /> Method to Keep Spill Container Empty: ❑x Drain Valve ❑x Drain Valve Z Drain Valve ❑ Drain Valve <br /> ❑ Onsite Pump ❑ Onsite Pump ❑ Onsite Pump ❑ Onsite Pump <br /> ❑ Other (Specify in V.) ❑ Other (SpeE L❑ Other (Specify in V) ❑ Other (Specify in V) <br /> IV. SUMMARY OF TESTING RESULTS <br /> Spill Container Test Results : ❑x Pass ❑ Fail (] Pass ❑ Fail ❑Q Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail' above must be explained in this section. Any additional comments may Ibe provided here . <br /> F Eu 12 2020 <br /> ENVIRONMENTAL HEALTH <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THISUES14 <br /> I hereby certify that the spill containers were tested in accordance with California Code of Regulations, Title 23, Division 3, <br /> Chapter 16, Section 2637.1 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council <br />