Laserfiche WebLink
SWRCB,January 2002 <br /> VII. PRODUCT PIPING CONTAINMENT TESTING INFORMATION <br /> Test Method Developed By: LJ Piping Manufacturer 0 Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: 0 Pressure ❑Vacuum ❑Hydrostatic <br /> �]Other(Spec) <br /> Test Equipment Used:Precision mechanical test gauge Equipment Resolution:0.0625" <br /> Piping Run#91 Piping Run#Diesel Piping Run#87 Piping Run# <br /> Piping Material: Fiberglass Fiberglass Fiberglass <br /> Piping Manufacturer: Smith Smith Smith <br /> Piping Diameter: 3.5" 3.5" 3.5" <br /> Length of Piping Run: Unknown Unknown Unknown <br /> Product Stored: Gasoline Diesel Gasoline <br /> Method and location of Boot in UDC Boot in UDC Boot in UDC <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 9:45 am 9:45 am 9:45 am <br /> Initial Reading(Ri): 5 psi 5 psi 5 psi <br /> Test End Time: 10:45 am 10:45 am 10:45 am <br /> Final Reading(RF): 5 psi 5 psi 5 psi <br /> Test Duration: 60 minutes 60 minutes 60 minutes <br /> Change in Reading(RF-RI): 0.00" 0.00^ 0.00" <br /> Pass/Fail Threshold or <br /> Criteria: 0.00" 0.00" 0.00" <br /> Test Result: I Z Pass ElFail L Pass ❑Fail Pass ❑Fail ❑ Pass Fail <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />