Laserfiche WebLink
Kennedy/Jenks Consultants <br /> APPENDIX A <br /> ow TYPICAL HYDRAULIC PUSH/DRIVE SAMPLING PROCEDURES <br /> l <br /> This appendix describes the equipment and procedures typically used by Kennedy/Jenks <br /> Consultants personnel for collecting soil and reconnaissance groundwater samples with a <br /> hydraulic push/drive system. <br /> EQUIPMENT <br /> • Portable, hydraulic push/drive sampling system <br /> ` • 6-inch long, 1-314-inch O.D. stainless steel or brass liners and liner sealing materials <br /> (Teflon sheets, plastic end caps, Ziploc plastic bags) <br /> • Type it Portland cement <br /> • 1-inch O.D. Schedule 40 PVC screen (0.010-inch slot size) <br /> t <br /> • 1-inch O.D. Schedule 40 PVC blank casing <br /> • 314-inch diameter stainless steel or Teflon bailer <br /> • FID or PID organic vapor analyzer <br /> • Water level indicator <br /> • Temperature, specific conductivity and pH meters <br /> • Equipment cleaning materials <br /> - Steam cleaner <br /> s - Generator <br /> - Stiff-bristle brushes <br /> - Buckets <br /> - High-purity phosphate-free liquid soap <br /> - Deionized water <br /> r - Rinsate collection system <br /> L 1 <br /> Personal protective equipment <br /> • Appropriate groundwater sample containers <br /> y <br /> • Chain-of-custody forms <br /> • Insulated sample storage container and ice substitute <br /> k <br /> 5 <br /> isl obX95W50073.00VptXworkplan5append-a.doc A-1 <br />