Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CDCR-NORTHERN CALIFORNIA YOUTH 7650 S NEWCASTLE RD, STOCKTON October 24, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 403 CCR 66265.173 Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> OBSERVATION: The following open hazardous waste storage containers were observed on-site: One green metal <br /> mobile open-top tank of used oil was observed in the auto shop without a lid. <br /> REGULATION GUIDANCE:A container holding hazardous waste shall always be closed during transfer and <br /> storage, except when it is necessary to add or remove waste. <br /> CORRECTIVE ACTION: Immediately close these containers and ensure all hazardous waste containers are closed <br /> when not adding or removing waste. Provide a corrective action statement and supporting documentation to the <br /> San Joaquin County Environmental Health Department within 30 days. <br /> This is a repeat violation, Class II. <br /> 409 CCR 66262.34(e)(2)Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely HW)per waste <br /> stream. <br /> OBSERVATION: The satellite accumulation area for used oil in the auto shop has a container that appears to be <br /> larger than 55 gallons. This storage exceeds the amount allowed for satellite accumulation. <br /> REGULATION GUIDANCE: (2)Except as provided in subsections(e)(2)(A)and (e)(2)(B)of this section, a process <br /> or group of processes meeting the requirements of subsection (e)(1)of this section, shall be subject to a single 55 <br /> gallon or one quart accumulation limit for that process or group of processes. <br /> (A) If not all of the wastestreams generated by a single process or group of processes located within the same <br /> physical area are compatible, a separate 55 gallon or one quart limit shall apply to each group of wastestreams that <br /> are compatible. <br /> (B) If the generator determines that using only one 55-gallon or one-quart container to initially accumulate specific <br /> compatible wastestreams is not practical (e.g., prevents recycling or requires unreasonable accumulation <br /> procedures)or safe from an environmental or worker/public health and safety standpoint,the generator may use a <br /> separate 55-gallon or one-quart container for those specific compatible wastestreams.The generator's <br /> determination shall be subject to review and approval by the Department at any time. <br /> CORRECTIVE ACTION: Immediately make the necessary arrangements to meet the satellite accumulation area <br /> amount limits. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> FA0003938 PR0513745 SCO01 10/24/2019 <br /> EHD 22-02 Rev.9/20/2019 Page 5 of 10 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />