01 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Pagel of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST)monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 11/08/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) Building# <br /> Unified Grocers, Inc. <br /> Business Site Address —City ZIP Code <br /> 1990 Piccoli Rd. Stockton 95215 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> TAIT Environmental Services, Inc. (714)560-8222 <br /> Mailing Address <br /> 11280 Trade Center Dr., Rancho Cordova,CA 95742 <br /> Name of UST Service Technician Performing the Certification(Print as shown on the ICC Certification) <br /> Jarrett Flewellyn <br /> Contractor/Tank Tester License# ICC Ceriificalion# ICC Certification Expiration Date <br /> 588098 18028164 103-29-2019 <br /> Monitoring System Training and Certifications List all applicable celtificaftons. Expiration Date <br /> Gilbarco Veeder Root-B36959 07-04-2019 <br /> III. RESULTS OF TESTING f SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> ❑X Monitoring System Set-up X Alarm History Report <br /> Was any monitoring equipment replaced? <br /> (if"Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section/l/below.) <br /> Was damage,debris, or liquid found inside any secondary containment systems? O <br /> (If'Yes,"describe what was found In section IV below.) El El <br /> Is all monitoring equipment operational per manufacturer's specifications? <br /> (If"No,"describe why in section IV below.) El 0 <br /> IV. COMMENTS <br /> If directed to use this section,describe how and when the issues were or will be corrected. <br /> The Power indicator light and Warning indicator light was replaced the monitoring panel. <br /> Removed approximately.25 gallons from the Hi Flow piping sump. <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations,Title 23, Division 3,Chapter 16,Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information(e.g.,manufacturers' checklists, monitoring system set-up,alarm history report, etc.)necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> f4—&'�ltu dips <br /> CERS=California Environmental Reporting System,ID=Identification,ICC=International Code Council,Y=Yes,N=No,NA=Not Applicable <br />