Laserfiche WebLink
UG010 <br /> UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181541 1/8/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Pacific Bell Telephone Co. dba AT&T California <br /> Business Site Address City ZIP Code <br /> 1812 Coley Ave. Escalon 95320 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Craig Feezell <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 588098 8374133 7/3/2021 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> Veeder-Root A23508 <br /> n n1 4 ?_020 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines(Specify): <br /> Used: +EALT <br /> x❑ IndustrY Code or Engineering Standard(Specify): Gln, <br /> PEI RP 1200 <br /> ❑ Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID: (By tank number, stored product. etc.) UG01 00001 <br /> What is the tank inside diameter?(Inches) 63.75" <br /> Is the fill piping secondarily contained? 0 Yes ❑ No ❑Yes ❑No ❑Yes ❑ No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? 0 Yes ❑ No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder-Root <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑Restricts Flow El Restricts Flow El Restricts Flow El Restricts Flow <br /> ❑AN Alarm ❑AN Alarm ❑AN Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ❑ No ❑Yes ❑ No ❑Yes ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 53.75" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No(Specify in V.) ❑No(Specify in V.) ❑ No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 0 Pass ❑ Fail j ❑ Pass ❑ Fail ❑Pass ❑Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail"must be explained in this section. Any additional comments may also be provided here. <br /> E]Check If Action Item(s)Are Present <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> ,�—,j�- "-Iq( <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AA/=Audible and Visual <br />