My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007960
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2801
>
2900 - Site Mitigation Program
>
PR0504943
>
ARCHIVED REPORTS_XR0007960
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 12:30:14 PM
Creation date
6/18/2020 12:08:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007960
RECORD_ID
PR0504943
PE
2951
FACILITY_ID
FA0004032
FACILITY_NAME
AMERICAN MOULDING & MILLWORK (FRMR)
STREET_NUMBER
2801
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11709001
CURRENT_STATUS
02
SITE_LOCATION
2801 WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.0 Results and Discussion <br /> This section presents a discussion of the March 1999 quarterly groundwater monitoring <br /> event conducted at the Site on March 18, 1999 <br /> The laboratory report provided by Quanterra was reviewed by Dames & Moore's data <br /> validation group in order to insure that the reported data results are accurate Results of the <br /> Dames & Moore QA/QC are included in Appendix B All data were determined to be <br /> acceptable for use <br /> 3.1 Groundwater Levels <br /> Groundwater was measured to be approximately 36 feet below ground surface on March <br /> 18, 1999 The direction of groundwater flow in March 1999 was towards the northeast, as <br /> illustrated in Figure 3 <br /> 3.2 TPH-D in Groundwater <br /> TPH-D groundwater results for samples collected on March 18, 1999 have been compiled <br /> with previous data in Table 3 TPH-D was not reported in any samples <br /> TPH as a hydrocarbon mixture not matching the fresh diesel standard was reported for <br /> samples MW-6 (380 ug/L) and its duplicate MW-Q (340 ug/L), collected from DMW-6 on <br /> March 18, 1999 TPH was also reported at a concentration of 82 ug/L in the sample <br />' collected at DMW-7 <br /> The unknown hydrocarbon was reported to represent TPH as a hydrocarbon mixture in the <br /> range of n-C10 to n-C40, which did not match the diesel fuel reference Review of <br />' chromatograms suggests that the unknown hydrocarbon appears to be a degraded diesel <br /> with an additional heavier weight hydrocarbon component <br /> 4.0 Future Activities <br /> Additional groundwater samples will be collected and analyzed for TPH-D during 1999, as <br />' required by the PHS/EHD The remaining two sampling events are tentatively scheduled <br /> for June and September 1999 Quarterly reports will be issued following each sampling <br /> event <br /> DAMES&MOORE 3 G 1WORDPROCZsaclafp19904 01 DOC <br />
The URL can be used to link to this page
Your browser does not support the video tag.