My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008137
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2801
>
2900 - Site Mitigation Program
>
PR0504943
>
ARCHIVED REPORTS_XR0008137
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 1:13:26 PM
Creation date
6/18/2020 12:09:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008137
RECORD_ID
PR0504943
PE
2951
FACILITY_ID
FA0004032
FACILITY_NAME
AMERICAN MOULDING & MILLWORK (FRMR)
STREET_NUMBER
2801
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11709001
CURRENT_STATUS
02
SITE_LOCATION
2801 WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> • Based on the model results which are supported by groundwater monitoring data, if <br /> groundwater level were to remain at approximately 54 to 70 feet bgs, there would be <br /> no adverse impact to water quality, health, or other beneficial uses of groundwater <br /> beneath the site <br /> 6 2 RECOMMENDATIONS <br /> ' It is recommended that this site be considered for conditional closure based on the above <br /> ' considerations and the following 5-year groundwater monitoring program <br /> • Quarterly water level measurements on the site monitoring wells <br /> • Sample the four site monitoring wells annually and analyze the samples for TPHd <br /> ' (EPA Method 8015) <br /> ' • Obtain monthly water level data from California Water Service in Stockton for their <br /> wells 77-01 and 21-01, which are the closest water supply wells to the Site <br /> r • Preparation of annual reports including hydrographs of water levels in site monitoring <br /> wells and California Water Service wells, a contour map showing groundwater <br />' gradient, tables of water level data and analytical results, and a short discussion of <br /> the monitoring results <br /> • If water levels increase to 50 feet bgs or detections of TPH/D in monitoring wells are <br /> reported, then the closure status and further monitoring should be reevaluated <br /> • If, at the end of 5 years (August 1999), water levels remain below 50 feet bgs and <br />' there are no detections of TPfl/D in groundwater at the site, then this site should be <br /> closed unconditionally <br />' SAC116 07 17 AUGUST 1994 <br /> DAMES & MOORE <br />
The URL can be used to link to this page
Your browser does not support the video tag.