My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011809
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2801
>
2900 - Site Mitigation Program
>
PR0504943
>
ARCHIVED REPORTS_XR0011809
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 12:30:12 PM
Creation date
6/18/2020 12:24:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011809
RECORD_ID
PR0504943
PE
2951
FACILITY_ID
FA0004032
FACILITY_NAME
AMERICAN MOULDING & MILLWORK (FRMR)
STREET_NUMBER
2801
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11709001
CURRENT_STATUS
02
SITE_LOCATION
2801 WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2801 West Lane,Stockton <br /> May 2005 <br />' Page 2 <br /> The screened intervals, completed depths, filter pack intervals of DMW-1 to DMW-7 <br /> included in Table 1 "Morutonng Well Construction Results" of the reports and previous <br /> quarterly sampling reports appeared to be incorrect The numbers in Table 1 are contrary to <br />' the numbers reported in Table 1 of Closure Request Report dated July 2001 prepared by URS, i <br /> quarterly sampling field records,and EHD official inspection reports at the time of well <br /> construction Please review the original well logs and make any necessary corrections to <br /> Table 1 in all future reports <br /> URS had previously submitted to EHD a well survey in Section 3 2 and Appendix A of the <br /> above-mentioned Closure Request Report URS reported in Section 3 2 that only one domestic <br /> well completed to 125 feet bsg within 2,000 feet south of the site Appendix A, comprised <br /> of a table and a map,identified 27 wells in the area The radius of the circle on the reap was <br /> not specified,but the radius of the circle appeared to far exceed 2,000 feet Since a distance <br /> scale was not provided on the reap,it is not known which wells labeled on the map are <br /> actually within2,000 feet of the site Also, the specific domestic well discussed in Section <br /> 3 2 could not be identified on the map or table According to the well-survey of the <br /> neighboring property, San Joaquin Catholic Cemetery,multiple private drinking and <br /> irrigation wells existed at the cemetery and St Joseph's Hospital None of these wells was <br /> identified or labeled on the well survey in Appendix A Since the Harding Cemetery is <br /> . located immediately adjacent to the site,it is likely many of these wells exist within 2,000 of <br /> the site The well survey in Appendix A is therefore potentially underreported Submit a <br /> comprehensive 2,000-foot well receptor survey to EHD or demonstrate the adequacy of the <br /> existing report by June 15,2005 The well survey should include a properly labeled map <br /> with distance scale and a 2,000-foot radius map,a list of the identified wells with <br /> corresponding addresses and well construction log Reliance solely on reviews of Water <br /> Well Drillers Reports at the California Division of Water Resources may be inadequate <br /> Conduct a door-to-door well survey if required A complete well survey with all wells <br /> existing within 2,000 feet of the site is required before a site can be considered for No <br /> Further Action status <br /> Donna Heran,RENS,Director <br /> Environmental Health Department <br /> Jeffrey Wong ' Senior REHS Nuel C Henderson,Jr,RG <br /> LOP/Site Mitigation Unit N LOP/Site Mitigation Unit N <br /> c URS Corporation—Anthony Mindhng, RG <br /> c RWQCB, Central Valley Re —James Barton,RG <br /> Region J <br />
The URL can be used to link to this page
Your browser does not support the video tag.