Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> ■ COUNTY <br /> ^ r1 `p' Greorne5S grows here, Time In: 1115 am <br /> Time Out: 12:15 pm <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: PINE APARTMENTS Date: 06/15/2020 <br /> Address: 610 E PINE ST, LODI 95240 <br /> Owner/Operator: COGLITORE HOLDING LLC Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #12 pH Level MAJOR <br /> OBSERVATIONS:The pool water pH was measure at 8. Reduce pH between 7.2 and 8 immediately. Do no open this pool <br /> prior to a re-inspection. Contact me at(209)468-9850 to schedule a re-open inspection. <br /> CALCODE DESCRIPTION:Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #2 Pool Enclosure <br /> OBSERVATIONS:One fence board of the West side fence is damaged;the West side of fence is wobbling. Repair and <br /> replace the fence board immediately and secure the West side fence within one month. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 31198) <br /> #3 Safety Signs <br /> OBSERVATIONS:Diarrhea sign is not location at the entrance area of a pool.The pool operator shall post at the entrance <br /> area of a public pool, a sign in letters at least 1 inch (25 mm)high, that clearly states that persons with diarrhea and persons <br /> who have had diarrhea within the prior 14 days shall not enter the pool water. Correct in a week. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31206) <br /> FA0000446 PR0360105 SCO01 06/15/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />