My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 12:54:47 PM
Creation date
6/18/2020 1:46:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N- U <br /> IVtU <br /> m <br /> UNDERGROUND STORAGE TANK AUG 19 2020 <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of s) <br /> Type of Action ❑ Installation Test ❑Repair Test ❑ Six Month t4dlR0NN. 36 Month Test <br /> I. FACILITY INFORMATION .j. ' <br /> '�M4767 Date of Secondly CQ aiAr 61est <br /> usiness Name 5.ame as Faah me or A- olio usioess As) UU�� LL LLUU <br /> awrence �Ivermore Vallona �a orMalorles Bldg. 879 <br /> aTT 04i teirral Hollow Road racy Ti9ft <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Brian Thornton 209-834-0792 <br /> Contractor I Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> CSLB #724513 A, C10, HAZ 5024962-UT, UC / U1 2-27-22 / 1-05-21 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (By tank number,stored product, etc.) A Unleaded B Diesel C D <br /> Tank Containment <br /> # <br /> Tightness Test Result 0 Pass ❑ Fail ❑ NA M Pass ❑ Fail ❑NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA <br /> Product Piping Containment , . "F+;i'w,zap• Y , i , _ + .r,;, ��r�"; <br /> Tightness Test Result 0 Pass ❑ Fail ❑NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA <br /> Communication Test Result 0 Pass ❑ Fail ❑NA ❑Pass ❑ Fail ®NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA <br /> Remote Fill Piping Containment A ., <br /> ;-i <br /> •r.,Q. a r. ',' i?r✓ n9 ,r.n 1 <br /> Tightness Test Result ❑Pass ❑ Fail M NA ❑Pass ❑ Fail M NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑ Fail 0 NA ❑Pass ❑ Fail M NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment p» <br /> s <br /> Tightness Test Result ❑Pass ❑ Fail 0 NA ❑Pass ❑ Fail 0 NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑ Fail 0 NA ❑Pass ❑ Fail 0 NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Vapor Recovery Piping Containment t "` �'. `' " y:x <br /> Tightness Test Result ❑Pass ❑ Fail M NA ❑Pass ❑ Fail 0 NA ❑ Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Communication Test Result ❑Pass ❑ Fail 0 NA ❑Pass ❑ Fail 0 NA ❑ Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Turbine i Product Piping Sump <br /> Tightness Test Result ®Pass ❑ Fail ❑NA 0 Pass ❑ Fail ❑NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Fill Riser Sump ? MCI, ' <br /> > .. <br /> Tightness Test Result ❑Pass ❑ Fail M NA ❑Pass ❑ Fail M NA ❑ Pass ❑Fail ❑ NA ❑ Pass ❑Fail p NA <br /> VENT i TRANSITION SUMP ID: e Unleaded b Diesel C d <br /> Tightness Test Result ❑Pass ❑ Fail 0 NA ❑Pass ❑ Fail M NA ❑ Pass ❑Fail ❑ NA ❑ Pass ❑Fail ❑NA <br /> UDC ID: 1 Unleade 2 Un7eaded 3 Iese 4 <br /> Tightness Test Result a Pass ❑ Fail ❑NA M Pass ❑ Fail ❑ NA 0 Pass ❑Fail ❑NA ❑ Pass ❑Fail ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑ Fail ❑NA ❑Pass ❑ Fail ❑NA ❑ Pass ❑Fail ❑NA ❑ Pass ❑Fail ❑NA <br /> UDC ID: 9 10 1 11 12 <br /> Tightness Test Result ❑Pass ❑ Fail ❑NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑Fail ❑NA ❑ Pass ❑Fail ❑NA <br /> All items marked"Fall"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3, Chapter 16,Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=Irtemational Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment <br /> UN-054 www.unidocs.org 116-Rev.06/14118 <br />