My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:34 AM
Creation date
6/18/2020 1:53:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> i <br /> i <br /> I <br /> Environmental ' Health Department <br /> � AN < � <br /> I <br /> G ye <br /> I Facility Name:. Facility Phone: Date: <br /> COUNTRYSIDE LIQUORS & GAS (209) 368-5380 March 30, 2020 <br /> Facility Address: CERS to: <br /> 14971 N HWY 88 , LODI , CA 95240 10180623 <br /> Inspection Contact Title: Phone: <br /> Bikram Sodhi Manager (209) 931 -3674 <br /> Inspection Type: r236, <br /> ogram: <br /> ROUTINE INSPECTION - Operating Permit - UST FACILITY <br /> Consent For: Consent Given By: <br /> I@ Inspection I@Photos ❑ Samples Bikram Sodhi, Manager <br /> Service Technician Onsite: Exp. Date: Designated Operator: Exp. Date: <br /> David Winkler 01 /22/2022 Alex Jabbari 10/01 /2020 <br /> Service 'Technician Manufacturees Training: <br /> VR, 02/09/22; VMI , 11 /07/21 ; SB, 11 /29/20 <br /> CCR Title 23 Calrome Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Reguialions <br /> V = Violation R = Repeat violation COS = Corrected on site during Inspection <br /> t $11 �It ' . ...� <br /> lot HSC 25284; CCR Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees o V o R ❑ COS <br /> 2711 (d) <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V o R o COS <br /> 103 HSC 25292.21 25299.30 Failure to submit and maintain complete and current financial responsibility documents o V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current o V o R o COS <br /> 105 CCR 2832(d)(1 ), Failed to have an approved UST monitoring plan o V o R ❑ COS <br /> 2634(d) <br /> j 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V o R o COS <br /> 2634(e) <br /> 107 CCR 2632(d), 2641 (1 Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 2711 (a) <br /> j 108 CCR 2637, 26311 Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 2643(g) <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months o V o R o COS <br /> 110 CCR 2637(e), 2637(1) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test o V o R o COS <br /> 111 CCR 2638, 26410), Failed to test monitoring and leak detection equipment every 12 months o V o R o COS <br /> 2715(f) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance o V o R o COS <br /> f 113 CCR 2638(c), 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test ❑ V o R ❑ COS <br /> 114 CCR 2636(1)(3), 2643(c) No 0. 1 gph annual fine integrity test for pressurized piping, or within 30 days after repair o V o R o COS <br /> (3) <br /> 115 CCR 2715(a)(1)(B), "Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days ❑ V ❑ R 13 COS <br /> 2715(a)(3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification o V o R o COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining, recordkeeping, and inspection requirements o V o R o COS <br /> 118 CCR 2715(a)(1)(A), Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" ❑ V ❑ R o COS <br /> 2715(a)(2) <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of InstallationlModification o V o R o COS <br /> 121 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report ❑ V ❑ R o COS <br /> � 122 CCR 2631 , 2640.1 , Failure to submit and/or maintain documentation regarding compatibility for UST system components ❑ V ❑ R ❑ COS <br /> I <br /> 2665, 2711 <br /> i FA0000540 PR0231911 SCOOt 03/30/2020 <br /> EHD 23-01 Rev, 9/2012018 Page 1 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www.sjcehd . com <br /> i <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.