My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:34 AM
Creation date
6/18/2020 1:53:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> SANAOAQUIN <br /> -- C 0 U N T Y <br /> 6 Om = m � <br /> ON <br /> fly' <br /> j Facility Name: Facility Address: Date: <br /> COUNTRYSIDE LIQUORS & GAS 14971 . N HWY 88 , LOD) March 30, 2020 <br /> 314 HSC 25290.11 25290.2, Failed to have secondary containment or secondary containment not tight o V a R o COS <br /> 25291 <br /> � 315 HSC 25291 (e) Water in secondary containment not removed, analyzed, and properly disposed of (preJul 2003) o V o R o COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) o V ❑ R ❑ COS <br /> 25290.2(c3) <br /> 317 CCR 2636, 2643(c)(1 ), Line leak detector (LLD) not installed o V ❑ R o COS <br /> 2666(f) <br /> 318 CCR 2666(c), 2643(c) Leak detector failed to detect a 3. 0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> i <br /> 1 <br /> 319 CCR 2635, 2637.1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested o V o R o COS <br /> 2665, 2712 <br /> i <br /> 320 CCR 26359 2637.21 Failure to comply with the Installation, inspection, or record keeping of the overfill prevention o V o R o COS <br /> 2665, 2712 <br /> 321 CCR 2635(c)(1 ) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> F322HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status a V o R o COS <br /> HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> CCR 2717.1 (g) Tampered with red tag o V ❑ R ❑ COS <br /> 325 CCR 2717. 1 (1), Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST o V ❑ R ❑ COS <br /> 25292.3(c) <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑ V o R ❑ COS <br /> 327 CCR 2631 ,1 , 2660(m) UST system not compatible with the substance stored a V ❑ R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ RJoCOS <br /> 329 HSC 25298; CCR 2670, Failed to comply with all permanent closure requirements o V o <br /> 2672 <br /> 330 CCR 2636(1), 2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm o V ❑ <br /> 2666(Q <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow Into the sump in the event of a leak (i.e. , failure to remove test boot). o V o R o COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards o V o R o COS <br /> 2666(b&e) <br /> 333 CCR 2835, 2836(b), Failure to comply with the cathodic protection system requirements ❑ V o R ❑ COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Singlewwalled pipe not upgraded to double-walled interstitially monitored pipe during repair o V o R ❑ COS <br /> ! 335 CCR 26301 26320 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party o V o R o COS <br /> 2644.1 <br /> 336 HSC 25292.3(c)(1 )(C) Owner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipe o V o R o COS <br /> x <br /> ell <br /> me ell <br /> Ce�°n Pettzlping ..� <br /> ri <br /> _ � <br /> 401 CCR 2636(a)(3), Suction piping not property sloped or incorrectly located check valve o V o R o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring / maintain records for single-walled conventional suction (pre 1964) o V o R ❑ COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0,1 gph test for single-walled conventional suction systems (pre-Jan 1964) a V o R o COS <br /> 404 CCR 2643(e) 2661 (f) 01 gph line <br /> test for smgie-walled gravity piping not pet7t <br /> pair (pre-1984) ❑ V o R o COS <br /> 2010 See below Unlisted General violation ❑ V ❑ R o COS <br /> FA0000540 PR0231911 SC001 03130/2020 <br /> Underground Storage Tank Program OIR <br /> EHD 23-01 Rev. 912012019 Page 3 of 6 <br /> 1868 E. Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 ( WWw.sjcehd. com <br /> I <br /> i <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.