Laserfiche WebLink
QUIN <br /> SAN 10AQUIN Environmental Health Department <br /> Nell <br /> i EIle ` j COUNTY Wayne Fox , REHS , Interim Director <br /> ,cP <br /> IFO Greatness grows here . PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> April 15 , 2020 <br /> CHRIS AZU <br /> CHARLES E THOMAS COMPANY INC . <br /> 13701 ALMA AVE <br /> GARDENA , CA 90249 <br /> Re : TESORO ( SPEEDYWAY) #68153/4612 SR0081950 <br /> 2448 W KETTLEMAN LN <br /> LODI , CA 95242 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to replace test boots and penetration fittings in the <br /> 87 , 91 gasoline and diesel STP sumps on the underground storage tank ( UST) system at the above <br /> noted address . The plan check service request has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustsigov . orq for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . Visual inspection of the penetration fittings/piping within the STP sumps for any leaks <br /> b . A secondary containment test must be performed on the STP containment sumps in <br /> accordance with the manufacturers guidelines or equivalent and test results submitted to <br /> the EHD within 30 days of testing . <br /> 4 . Secondary containment testing for the sumps is required six months after installation . Provide <br /> 48 hours notification to the EHD when this test is scheduled . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer( s ) of the <br /> component (s) being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 F 209 464 -0138 1 www . sjcehd . com <br />