My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:20:11 PM
Creation date
6/18/2020 2:16:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SPEEDWAY) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
272
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page i of i) <br />Type of Action ❑ Installation Inspection ❑ Repair Inspection ® 36 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID <br />10181487 <br />Date of Overfill Prevention Equipment Inspection <br />15/21/20 <br />Business Name (Same as Facility Name or DBA-Doing Business As) <br />Speedway 4612 <br />Business Site Address <br />2448 W Kettleman Ln. <br />City <br />Lodi <br />ZIP Code <br />95242 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) <br />Brian McPheely 1(408) <br />Phone # <br />971-2445 <br />Contractor I Tank Tester License # <br />485184 <br />ICC Certification # <br />8822062 <br />ICC Certification Expiration Date <br />11 /1 /21 <br />Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />OPW # 104773 <br />Franklin Fueling Site Safety # 1014303708 <br />III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method <br />Used: <br />la Manufacturer Guidelines (Specify): F.F. Defender <br />❑ Industry Code or Engineering Standard (Specify): ENVIRONMENTAL HEALTH <br />❑ Engineered Method (Specify). 7EP, <br />Attach the inspection procedures and all documentation required to determine the results. <br /># of Attached Pages <br />TANK ID: (By tank number, stored product, etc.) <br />1-87 <br />2-91 <br />3-Diesel <br />What is the tank inside diameter? (Inches) <br />92 <br />92 <br />92 <br />Is the fill piping secondarily contained? <br />m Yes ❑ No <br />m Yes ❑ No <br />® Yes ❑ No <br />❑ Yes ❑ No <br />Is the vent piping secondarily contained? <br />❑ Yes © No <br />❑ Yes © No <br />❑ Yes ® No <br />❑ Yes ❑ No <br />Overfill Prevention Equipment Manufacturer(s) <br />Franklin <br />Franklin <br />Franklin <br />Defender <br />Defender <br />Defender <br />What is the overfill prevention equipment response <br />when activated? <br />(Check all that apply.) <br />® Shuts Off Flow <br />❑ Restricts Flow <br />❑ A/V Alarm <br />{a Shuts Off Flow <br />❑ Restricts Flow <br />❑ A/V Alarm <br />0 Shuts Off Flow <br />❑ Restricts Flow <br />❑ A/V Alarm <br />❑ Shuts Off Flow <br />❑ Restricts Flow <br />❑ A/V Alarm <br />Are flow restrictors installed on vent piping? <br />❑ Yes 0 No <br />❑ Yes 0 No <br />❑ Yes [Z No <br />❑ Yes ❑ No <br />At what level in the tank is the overfill prevention set <br />to activate? (Inches from bottom of tank.) <br />83.75 <br />83.75 <br />83.75 <br />What is the percent capacity of the tank at which the <br />overfill prevention equipment activates? <br />95.88% <br />95.88% <br />95.88% <br />Is the overfill prevention in proper operating condition <br />to respond when the substance reaches the <br />appropriate level? <br />0 Yes <br />❑ No (Specify in V.) <br />0 Yes <br />❑ No (Specify in V.) <br />® Yes <br />❑ No (Specify in V.) <br />❑ Yes <br />❑ No (Specify in V.) <br />IV. SUMMARY OF INSPECTION <br />RESULTS <br />Overfill Prevention Inspection Results ❑ Pass 0 Fail I ❑ Pass m Fail 1 ❑ Pass m Fail ❑Pass ❑ Fail <br />V. COMMENTS <br />Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br />87, 91 and Diesel Flappers are set over 95% and Failed. <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, Title 23, <br />Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br />UST Service Technician Signature <br />If the facility has more components than this form accommodates, additional copies of this page may be attached. <br />CERS = California Environmental Reporting System, ID = kientification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.