Laserfiche WebLink
= opauiryp'GZ SAN 10AQUIN Environmental Health Department <br /> Wayne Fox REHS , Interim Director <br /> COUNTY Y <br /> c.` PROGRAM COORDINATORS <br /> gCIFOF�`P , Greatness grows {leve . Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Michael Kith , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Melissa Nissim , REHS <br /> May 8 , 2020 <br /> MEGAN MITCHELL <br /> ELITE IV CONTRACTORS <br /> 2535 WIGWAM DR <br /> STOCKTON , CA 95205 <br /> Re . Manteca Liquor Food and Gas <br /> 8%1N Main St SR0082007 <br /> Manteca , CA 95336 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of <br /> the application for a permit to remove and install two new dispensers with conversion frames on <br /> the underground storage tank ( UST) system at the above noted address . The permit has been <br /> approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior <br /> to commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust ( siaov . org for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be <br /> scheduled within five days of plan check service request approval . <br /> • Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs) any potential leaks from piping and fuel filters must drain directly into <br /> UDCs . <br /> • Visual inspection of the piping within the dispensers for any leaks . <br /> • Verification of the installation of the Bravo CONV- 62000 conversion frame per <br /> manufacturer instructions . <br /> • If concrete will be broken near the tank , piping or sumps a secondary containment test <br /> must be performed on the affected components once concrete is poured in accordance <br /> with the manufacturer' s guidelines and test results submitted to the EHD within 30 days <br /> of testing . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible <br /> valid , current contractor' s licenses issued by the Contractors State License Board <br />