Laserfiche WebLink
: SA NUJ FAQ U I N Environmental Health Department <br /> ._ COUNTY <br /> Time In: 130 pm <br /> ^'•ti7FOpt�% Greotness grows here. <br /> Time Out: 2:15 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: RIVERWOOD APARTMENTS Date: 06/18/2020 <br /> Address: 4514 MCGAW ST, STOCKTON 95207 <br /> Owner/Operator: ABL PROPERTIES INC Telephone: (209)474-8521 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:Spa is closed due to COVID-19. If it reopens,write in capacity. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Light is not working. Replace by 2 weeks. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:Spa has a small amount of pits. Plan to re-plaster in the near future. Contact this department and pull <br /> permit for remodel. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31088) <br /> #24 VGB Suction Covers <br /> OBSERVATIONS:Cover on wall fell off. If spa is re-opened this season, cover shall be installed (manager currently has <br /> cover)/ <br /> CALCODE DESCRIPTION:All suction outlets shall be equipped with suction covers that meet the applicable ANSIIAPSP-16 performance <br /> standards. (CBC 31378) <br /> FA0002481 PR0360254 SCO01 06/18/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />