f Application for Authority To Construct/Permit To Operate <br /> San Joaquin Valley Unified Air Pollution Control District <br /> Thrifty Oil Co. Station #171 ,I <br /> August 25, 1998 " <br /> Page 3 <br /> IL <br /> Maximum Daily Emission for TPH (thermal): <br /> MAE _(91 ppmv)x(10-6)x(200 cfm)x(lbmole/379 cf)x(86 Ib/lbmole)x(60x24 min/day) <br /> = 5.95 lb/day :i <br /> Maximum Daily Emission for benzene (thermal): <br /> MAE _(0.9 ppmv)x(10-6)x(200 cfm)x(1bmo1e/379 cf)x(78 1b/1bmo1e)x(60x24 min/day) <br /> =0.053 lb/day <br /> 's <br /> Inlet TPH concentration(catalytic) = 3,500 ppmv or less ;� <br /> Assume benzene is 1%of TPH, inlet benzene concentration(catalytic) = 35 ppmv or less <br /> Outlet TPH concentration(catalytic)=less than 105 ppmv <br /> i Outlet benzene concentration(catalytic) =less than 1.1 ppmv <br /> i <br /> �i <br /> Maximum Daily Emission for TPH (catalytic): <br /> MAE _ (105 ppmv)x(10')x(200 cfrn)x(Ibmo1e/379 cf)x(86 lb/lbinole)x(60x24 min/day) <br /> r <br /> =6.86 lb/day <br /> Maximum Daily Emission for benzene(catalytic): <br /> MAE _(1.1 ppmv)x(10 )x(200 cf n)x(lbmole/379 cf)x(7,8 1b/1bm01e)x(60x24 min/day) k <br /> = 0.065 lb/dayi ' <br /> Treatment Unit Specifications <br /> ► Manufacturer=Baker Furnace, Inc. <br /> ► Model=200 CFM, skid mounted model ' <br /> ► Type=Thermal oxidizer, convertible to catalytic oxidizer <br /> ► <br /> Blower=Roots Universal RAI 36 with 5 h motor with inlet and outlet silencers <br /> p <br /> ► Standard equipments: knock-out pot; air filters; automatic air dilution system; natural <br /> gas/propane supplemental fuel; Eclipse MVTA combustion <br /> burner; control panel with controllersand chart recorder r <br /> ► Safety Interlocks: air proving switch; high/lAr gas pressure switch; high <br /> temperature limit controller; FM approved Flame Safety Device; <br /> LEL combustible sensor,controller aril recorder; Flame Arrester; <br /> FM approved supplemental fuel train; alarm card in process <br /> temperature controller <br /> ► Combustion burner: Eclipse MVTA- 500,000 BTU/hr <br /> ► Effluent stack: One (1) 32.5 inch diameter, 13`ft high t <br /> 'llk <br />