7.2 Pumping Well EW-513 GeoHydrologlc Consultants, Inc <br /> Monitoring well EW-5D is a 4-inch diameter well that is installed to a depth of 85 feet <br /> bgs, with 0 010-inch slotted well screen from 65-85 feet bgs The sand pack extends <br /> ' approximately two feet above the top of screen Groundwater appears to be present under <br /> unconfined water-table conditions Static groundwater was measured prior to conducting <br /> the pumping test in EW-5D at a depth of 47 47 feet bgs, indicating an estimated aquifer <br /> thickness of approximately 40 feet <br /> The pumping test was started at 6 35 AM on March 31, 2005 and was maintained at a <br /> constant pumping rate of approximately 2 3 gallons per minute (gpm) for 745 minutes, <br /> terminating at 7 00 PM that evening A total of approximately 1,400 gallons of water was <br /> removed during the pumping test and stored onsite in a 4,000-gallon polyethylene Baker <br /> ' Tank All water generated during the test was vacuum trucked from the tank and properly <br /> recycled/disposed Drawdown was measured and recorded at regular intervals throughout <br /> the test from the pumping well EW-513 and observation wells EW-5S, MW-4, TB-10, <br /> and TB-7 The maximum observed drawdown in the extraction well EW-5D was 5 40 <br /> feet at the end of the test, while the maximum drawdown measured in observation well <br /> EW-5S was 0 05 feet at 385 minutes, the maximum drawdown measured in observation <br /> ' well MW-4 was 0 05 feet at 325 minutes, the maximum drawdown measured in <br /> observation well TB-7 was 0 10 feet at 235 minutes, and the maximum measured <br /> drawdown in observation well TB-10 was 0 08 feet at 265 minutes <br />'.! Figure 6A illustrates the drawdown graph for the pumping well EW-5D and Figures 613 <br /> and 6C illustrates the drawdown graphs for observation wells TB-7 and TB-10 The <br /> drawdown and recovery data for this well is summarized in Table l0A and copies of <br /> field data are included in Appendix D <br />' Analysis of drawdown data for EW-5D is presented in Table 7 2-1, TB-7 is presented in <br /> Table 7 2-2, and TB-10 is presented in Table 7 2-3 An estimated saturated thickness of <br /> 40 feet was assumed from the well depth, static groundwater level the day of the pumping <br />' test, and the lithologic logs for the Site According to Todd (1980), hydraulic <br /> conductivities in this range are representative of soils consisting of silt to medium sand, <br /> which is representative of the sediment described in the boring log for EW-5D at the <br /> depths of this well It should be noted that if vertically thinner saturated thicknesses were <br /> assumed, the calculated hydraulic conductivity would increase accordingly <br /> 1 <br /> TOC 171 Pilot Study Page 19 <br />