My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLARK
>
3927
>
2200 - Hazardous Waste Program
>
PR0514138
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2021 10:49:37 AM
Creation date
6/23/2020 11:02:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0514138
PE
2250
FACILITY_ID
FA0010034
FACILITY_NAME
PNP Stockton #80
STREET_NUMBER
3927
Direction
E
STREET_NAME
CLARK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17917109
CURRENT_STATUS
01
SITE_LOCATION
3927 E CLARK DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
696
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J O A Q U I N Environmental Health Department <br /> C.C_3 U N I Y <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PNP Stockton#80 3927 E CLARK DR, STOCKTON October 10, 2019 <br /> Tank Management <br /> 502 CCR 66265.192(a) Failed to comply with new hazardous waste tank system assessment requirements ❑V ❑R ❑COS <br /> 503 CCR 66265.192(k) Hazardous waste tank assessment is incomplete ■V ❑R ❑COS <br /> 504 CCR 66265.192(1)/(m) Failed to notify EHD before replacing identical or equivalent equipment ❑V ❑R ❑COS <br /> 505 CCR 66265.193 Tank system lacks adequate secondary containment or leak detection ❑V ❑R ❑COS <br /> 506 CCR 66265.194 Failed to maintain tanks for storage of incompatible materials or prevent spills and overfills ❑V ❑R ❑COS <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite ■V ❑R ❑COS <br /> 508 CCR 66265.195(b) Failed to inspect HW tank cathodic protection system ❑V ❑R ❑COS <br /> 509 CCR 66265.196 Failed to immediately respond to spills and leaks from hazardous waste tank system ❑V ❑R ❑COS <br /> 510 CCR 66265.197 Failed to properly close a hazardous waste tank system ❑V ❑R ❑COS <br /> 511 CCR 66262.34(a)(1). Failure to comply with hazardous waste tank air emission requirements ❑V ❑R ❑COS <br /> 66265.202 <br /> 512 CCR 66265.192(h) Failure to obtain a reassessment of a tank system within 5 years or as required ❑V ❑R ❑COS <br /> Labeling and Storage <br /> 601 CCR 66262.34(a) Stored hazardous waste on site longer than 90 days without a permit or authorization ❑V ❑R ❑COS <br /> 602 CCR 66262.34(e)(1)(B) Stored satellite accumulated waste on site longer than one year or 90 days after fill date ❑V ❑R ❑COS <br /> 603 CCR 66262.34(e)(1)(C) Failed to mark initial accumulation start date on satellite containers ❑V ❑R ❑COS <br /> 604 CCR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days ❑V ❑R ❑COS <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste ■V ■R ❑COS <br /> 606 CCR 66266.81(a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption �V ❑R ❑COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not properly managed and labeled ■V ■R ❑COS <br /> 608 CCR 66266.130 Failed to properly manage used oil and fuel filters ■V ■R ❑COS <br /> (609HSC 25143.2,25173.9 Failed to meet requirements for claimed excluded recyclable materials ❑V ❑R ❑COS <br /> HSC 25200.3.1(b) Failure of laboratory to comply with hazardous waste accumulation area requirements ❑V ❑R ❑COS <br /> Universal Waste M 111CCR 66273.32(a) Failed to notify the EPA RA to obtain an EPA ID#prior to accumulating>5000kg of UW ❑V ❑R ❑COS <br /> CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW ❑V ❑R ❑COS <br /> 703 CCR 66273.33(a) UW handler failed to store UW batteries in a manner that prevents release to the environment ❑V ❑R ❑COS <br /> 704 CCR 66273.33(b) UW handler failed to properly manage universal waste lamps ❑V ❑R ❑COS <br /> 705 CCR 66273.33(c) UW handler failed to properly manage mercury containing universal waste ❑V ❑R ❑COS <br /> 706 CCR 66273.33.5 UW handler failed to prevent release of universal waste electronic devices,CRTs or CRT glass ❑V ❑R ❑COS <br /> 707 CCR 66273.34 UW handler(UWH)failed to label universal waste to identify type of universal waste ❑V ❑R ❑COS <br /> 708 CCR 66273.35 UWH stored UW onsite greater than one year or was unable to demonstrate storage time ❑V ❑R ❑COS <br /> 709 CCR 66273.36 UWH failed to train employees and maintain records on UW handling and emergency procedures ❑V ❑R ❑COS <br /> 710 CCR 66273.39 UWH failed to keep complete records of each shipment of universal waste for three years ❑V ❑R ❑COS <br /> FA0010034 PR0514138 SCO01 10/10/2019 <br /> EHD 22-03 Rev.9/20/2019 Page 3 of 22 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.