My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLARK
>
3927
>
2200 - Hazardous Waste Program
>
PR0514138
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2021 10:49:37 AM
Creation date
6/23/2020 11:02:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0514138
PE
2250
FACILITY_ID
FA0010034
FACILITY_NAME
PNP Stockton #80
STREET_NUMBER
3927
Direction
E
STREET_NAME
CLARK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17917109
CURRENT_STATUS
01
SITE_LOCATION
3927 E CLARK DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
696
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 4 <br /> Summary of CCR Requirements <br /> Pick-n-Pull <br /> Stockton, California <br /> Code Section Requirement 01 02 03 04 Al A2 A3 A4 Customer Drop-Off <br /> 66265. 193(e)(2) provided with an exterior moisture barrier or be otherwise NA NA NA NA NA NA NA NA NA <br /> (F) designed or operated to prevent migration of moisture <br /> into the vault if the vault is subject to hydraulic pressure. <br /> 66265. 193(e)(3) Double-walled tanks shall be: designed as an integral NA NA NA NA NA NA NA NA Double walled tank - inner tank with <br /> (A) structure (i .e. , an inner tank within an outer shell ) so that outer shell . See Appendix C for <br /> any release from the inner tank is contained by the outer specifications <br /> shell ; <br /> 66265. 193(e)(3) Double-walled tanks shall be: protected , if constructed of NA NA NA NA NA NA NA NA HDPE tank, no corrosive protection <br /> (B) metal , from both corrosion of the primary tank interior for HDPE. <br /> and the external surface of the outer shell ; and <br /> 66265. 193(e)(3) Double-walled tanks shall be: provided with abuilt-in , NA NA NA NA NA NA NA NA Visual daily inspections <br /> (C) continuous leak detection system capable of detecting a <br /> release within 24 hours or at the earliest practicable time, <br /> if the owner or operator can demonstrate to the <br /> Department, and the Department concurs, that the <br /> existing leak detection technology or site conditions will <br /> not allow detection of a release within 24 hours. <br /> 66265. 193 (f) Ancillary equipment shall be provided with full secondary <br /> containment (e.g . trench , jacketing , double-walled piping) <br /> that meets the requirements of subsections (b) and (c) of <br /> this section except for: <br /> 66265. 193 (f)( 1 ) aboveground piping that are visually inspected for leaks Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. NA <br /> on a daily basis <br /> 66265. 193 (f)(2) welded flanges, welded joints, and welded connections Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. Daily visual inspections. NA <br /> that are visually inspected for leaks on a daily basis <br /> 66265. 193 (f)(3) seatless or magnetic coupling pumps and seatless NA NA NA NA NA NA NA NA NA <br /> valves, that are visually inspected for leaks on a daily <br /> basis and <br /> 66265. 193 (f)(4) pressurized above ground piping with automatic shut-off Pumped and/or gravity drained . Pumped and/or gravity drained . Pumped and/or gravity drained . Pumped and/or gravity drained . Pumped and/or gravity drained . Pumped and/or gravity drained . Pumped and/or gravity drained . Pumped and/or gravity drained . NA <br /> devices that are visually inspected for leaks on a daily <br /> basis. <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.