SYSTEM SET-UP REPORT (Page 2) <br /> T 3:Die5el LEAK TEST METHOD OUTPUT RELAY SETUP EVR/ISD SETUP <br /> PRODUCT CODE B - - - - - - - - - - - - - - - - - - - - - - - <br /> THERMAL COEFF : .000450 TEST ON DATE : ALL TANK <br /> TANK DIAMETER 96.00 JUL 23, 2010 R 1:91 <br /> TANK PROFILE 4 PTS START TIME : DISABLED TYPE: EVR TYPE: VACUUM ASSIST <br /> FULL VOL 7950 T£ST 'RATE :0.20 GAL/HR STANDARD VACUUM ASSIST TYPE <br /> 72.0 INCH VOL 6828 DURATION : 2 HOURS NORMALLY CLOSED HEALY VAC <br /> 48.0 INCH VOL 4299 <br /> 24.0 INCH VOL 1629 TST EARLY STOP:DISABLED TANK #: 2 NOZZLE A/L RANGE <br /> MAX: 1 .15 MIN: 0.95 <br /> LEAK TEST REPORT FORMAT <br /> FLOAT SIZE: 4.0 IN, NORMAL IN-TANK ALARMS VAPOR PROCESSOR TYPE <br /> WATER WARNING 1 .0 T 21LOW PRODUCT ALARM NONE <br /> HIGH WATER LIMIT: 2.0 LIQUID SENSOR SETUP LIQUID SENSOR ALMS <br /> MAX OR LABEL VOL: 7950 - - - - - - - - - - - - L 2:SENSORLOUT ALARM ARM ANALYSIS TIMES <br /> OVERFILL LIMIT 90% L 2:SHORT ALARM TIME: 10:00 AM <br /> 7155 L 1 :DIESEL STP DELAY MINUTES: 1 <br /> HIGH PRODUCT 95% TRI-STATE (SINGLE FLOAT) l�aD SITE ALARMS <br /> 7552 CATEGORYSTPSUMP ISD GROSS PRES FAIL <br /> ACCEPT HIGH ORVk: <br /> DELIVERY LIMIT 10% ISD DEGRD FRES FAIL <br /> DISABLED <br /> 795 L 2:91 STP ISD VAPOR LEAK FAIL DISABLED <br /> LOW PRODUCT 600 TRI-STATE (SINGLE FLOAT) ISD VP PRES FAIL ISD HOSE TABLE <br /> LEAK ALARM LIMIT: 99 CATEGORY : STP SUMP IDFPFL <br /> HL AA RR <br /> ISD HOSE ALARMS ------------------------ <br /> SUDDEN LOSS LIMIT: 99 ALL:GROSS COLLECT FAIL 01 01 01 02 01 00 <br /> TANK TILT 0.00 L 3:87 STP ALL:DEGRD COLLECT FAIT: 02 02 02 02 01 00 <br /> PROBE OFFSET 0.00 TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL 03 03 03 02 02 00 <br /> CATEGORY : STP SUMP R 2:87 04 04 04 02 02 00 <br /> SIPHON MANIFOLDED TANKS TYPE: <br /> TO: NONE L 4:87 ANNULAR STANDARD ISD AIRFLOW METER MAP <br /> LINE t°IANIFOLDED TANKS TRI-STATE (SINGLE FLOAT) NORMALLY CLOSED ID SERIAL NUM LABEL <br /> T#: NONE CATEGORY ANNULAR SPACE <br /> - ------------------------- <br /> TANK #: 1 1 39364 1-2 <br /> LEAK MIN PERIODIC: 0% 2 75450 3-4 <br /> 0 L 5:91 ANNULAR IN-TANK ALARMS <br /> TRI-STATE (SINGLE FLOAT) T 1 :LOW PRODUCT ALARM ISD FUEL GRADE HOSE MAP <br /> LEAK MIN ANNUAL 0% CATEGORY : ANNULAR SPACE 1 2 3 4 <br /> 0 LIQUID SENSOR ALMS FP MHH MHH MHH MHH AA <br /> L 3:FUEL ALARM ---------------------_.- <br /> L 3:SENSOR OUT ALARM Q1 401 901 501 0 U I <br /> PERIODIC TEST TYPE L 3:SHORT ALARM <br /> L 6:DIESEL ANNULAR 02 402 902 502 D U 1 <br /> STANDARD TRI-STATE (SINGLE FLOAT) PRMS 03 403 903 503 0 U 2 <br /> ANNUAL TEST FAIL . CATEGORY : ANNULAR SPACE IISSITE <br /> L <br /> GROSS PRES FAIL 04 404 904 504 0 U 2 <br /> ALARM DISABLED ISD DEGRD PRES FAIL <br /> PERIODIC TEST FAIL ISD VAPOR LEAK FAIL LABEL TABLE <br /> ------------------------- <br /> ALARM DISABLED ISD HOSE ALARMS 1 : UNASSIGNED <br /> GROSS TEST FAIL ALL:DEGRD COLLECT FAII 2: BLENDS <br /> ALARM DISABLED ALL:FLOW COLLECT FAIL 3: REGULAR <br /> - 4: MID GRADE <br /> ANN TEST AVERAGING: OFF SMARTSENSOR SETUP DIESEL 5: PREMIUM <br /> 6: GOLD <br /> PER TEST AVERAGING: OFF - - - - - - - - - _ - - TYPE7: BRONZE <br /> STANDARD 8: SILVER <br /> TANK TEST NOTIFY: OFF CATEGORY AIR FLOW METER NORMALLY CLOSED 9: BLEND2 <br /> TNK TST SIPHON BREAKOFF 2:3-4 TANK #: 3 10: BLEND4 <br /> DELIVERY DELAY 5 MIN, CATEGORY AIR FLOW METER <br /> PUMP THRESHOLD 10.00% IN-TANK ALARMS <br /> 5 3:VAPOR PRESSURE T 3:LOW PRODUCT ALARM <br /> CATEGORY VAPOR PRESSURE <br /> LIQUID SENSOR ALMS SOFTWARE REVISION LEVEL. <br /> L 1 :FUEL ALARM VERSION 330.01 <br /> L 1 :SENSOR OUT ALARM SOFTWARE# 346330-100--5 <br /> L 1 :SHORT ALARM CREATED - 10.07. 3.17.25 <br /> S-MODULE# 330160-004-a <br /> SYSTEM FEATURES: <br /> PERIODIC IN-TANK TESTS <br /> ANNUAL IN-TANK TESTS <br /> ISG <br /> ©2018 Walton Engineering,Inc. <br />