Laserfiche WebLink
tank is fitted with a an 18 inch threaded manway with a 4-inch atmospheric vent on the primary tank,which <br /> is properly sized to this tank and the venting requirements as annotated for the desien by Snyder Industries. <br /> 15. AST secondary containment(material/design/listed) AST has secondary containment via single wall <br /> construction to completely capture product introduced into primary vessel. Secondary containment is via an <br /> impermeable steel berm,which has no openings other than the top,which was inspected,was tested,is intact <br /> and both AST and the berm are suitable for continued usaee. Leak detection is visually ascertained via <br /> visual inspection of secondary containment area. Berm containment capacity is approximately 450 gals. <br /> 16. Damage to AST or systems. No damage reported by Owner/Operator. Upon inspection,no evidence of <br /> weld breaks, punctures,cracks,or other structural damage to the berm. Upon inspection, there was no <br /> evidence of cracks,breaks,punctures or other structural damaee to the primary vessel. Leak detection is <br /> assured via inspections of the secondary containment. Poly thickness measured to 7.8 mm. average. Steel <br /> thickness of the berm was measured to .110 in. thickness,which would be in excess of steel thickness <br /> minimums under UL 142. <br /> 17.Comments Tank has a 1 '/4 in. closed fittine at base of tank. Tank had approximately 10 gals. of product <br /> at the time of the inspection. <br /> a. Dimensions of AST: Primary Vessel= 300 eallons capacity total <br /> Dimensions: Primary Tank: 38 in.Diam X 67 in. L./ lin. crown top ( 16 in. openine for product <br /> removal. <br /> Secondary Berm: 60 in.W X 73 in. L X 24 in.Ht <br /> b. Product stored: used (waste) Coolant: Specific Gravity=1.03 <br /> c. ( 1 ) 4 in. atmospheric vent on primary containment( 0 ) in. emergency vent on primary vessel <br /> d. ( 0 ) in. atmospheric vent on secondary containment( 0 1 in. emergency vent on secondary vessel <br /> PE certification <br /> 1 certify under penalty of law that this document and all attachments were prepared under my direction or supervision in <br /> accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. <br /> Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the <br /> information, the information submitted is, to be the best of my knowledge and belief, true, accurate, and complete. 1 am aware <br /> that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for <br /> knowing violations. <br /> I have reviewed the data and confirm it complies //does not comply_with CCR section 66265.192(k) <br /> Q�pFESS/pNq � T /� <br /> `^yam, Printe e of Re 'stereAPE <br /> �y <br /> aL111- <br /> M Ln <br /> CD z Signature of Registered PE <br /> -30 <br /> 087 <br /> EXP,. -30- 0 <br /> lqr CI Q <br /> 0 A �J <br /> (seal)Date /223�19 Registration Number j� 1 State <br />