Laserfiche WebLink
s e a W M9 <br /> Data Qualifiers and Definitionip <br /> -Qua i iers <br /> A SePRert CommenCs <br /> B Analyte was present in an associated method blank. • <br /> B Analyte was present in a sample and associated method b an grea er an L ut�ss han <br /> BQ1 No valid test replicates.Sample Toxicity is possible. Best result was reported. <br /> BQ2 No valid test replicates. <br /> BQ3 No valid test replicates. Final DO is less than 1.0 mg/L. Result may be greater. <br /> BQ4 Minor Dissolved Oxygen loss was observed in the blank water check,however,the LCS was within criteria,validating the batch. <br /> BQ Minor Dissolved Oxygen loss was observed in the blank water check <br /> C Possible laboratory contamination. <br /> • RPD was not within control limits.The sample data s re orted withft he ari ica ion. <br /> A Lesser amount of sample was used due to insufficient amount of sample supplied.— <br /> D2• Reporting limit is elevated due to sample matrix. Target analyte was not detected above the elevated reporting limit. <br /> D3 Insufficient sample was supplied for TCLP. Client was notified. TCLP was performed per the Client's instructions. <br /> DW Sample result is calculated on a dry weigh basis <br /> ' E Concentration is estimated because it exceeds the quan i ica ionimi s o e od. <br /> I The sample was read outside of the method required incubation period. <br /> J Reported value is estimated <br /> L The laboratory control sample(LCS)or laboratory control sample duplicate(LCSD)was out of control limits. Associated sample <br /> data was reported with qualifier. <br /> The matrix spike(MS)or matrix spike duplicate(MSD)was not within control limits due to matrix interference.The associated <br /> LCS and/or LCSD was within control limits and the sample data was reported without further clarification <br /> M1 The matrix spike(MS)or matrix spike duplicate(MSD)is not within control limits due to matrix interference. <br /> M2 The matrix spike(MS)or matrix spike duplicate(MSD)was not within control limits. The associated LCS and/or LCSD was not <br /> 4Dwithin control limits. Sample result is estimated. <br /> N1 Sample chromatography does not match the specified TPH standard pattern. <br /> NC The analyte concentration in the sample exceeded the spike level by a factor of four or greater, spike recovery and limits do not <br /> apply. <br /> P Sample was received without proper preservation according to EPA guidelines. <br /> P1 Temperature of sample storage refrigerator was out of acceptance limits. <br /> P2 The sample was preserved within 24 hours of collection in accordance wit EP 21 <br /> P3 Per Client request,sample was composited for volatile analysis. Sample compositing for volatile analysis is not recommended <br /> - due to potential loss of target analytes.Results may be biased low — • - <br /> 01 Analyte Calibration Verification exceeds criteria.The result is est ma e <br /> 02 Analyte calibration was not verified and the result was estimated. <br /> Q3 Analyte initial calibration was not available or exceeds criteria.The results estimated. <br /> S The surrogate recovery was out of control limits due to matrix interference.The associated method blank surrogate recovery <br /> was within control limits and the sample data was reported without further clarification. <br /> The associated surrogate recovery was out of control limits;result is estimated. <br /> S2 The surrogate was diluted out due to the presence of high concentrations of target and/or non-target compounds.Surrogatelm <br /> recoveries in the associated batch QC met recovery criteria. <br /> Internal Standard did not meet recovery limits.Analyte concentration is estimated <br /> T Sample was extracted/analyzed past the holding time. - <br /> T1 Reanalysis was reported past hold time due to failing replicates in the original analysis(BOD only). <br /> T2 Sample was analyzed ASAP but received and analyzed past the 15 minute Wing twe.— <br /> T3 Sample received and analyzed out of hold time per client's request. - <br /> T4 Sample was analyzed out of hold time per client's request. <br /> TS Reanalysis was reported past hold time. The original analysis was within hold time, but not reportable. <br /> T6 Hold time is indeterminable due to unspecified sampling time <br /> T7• 0Sample was analyzed past hold time due to insufficient time remaining at time o receip <br /> Definitions <br /> DF Dilution Factor W � IP <br /> MDL Method Detection imi . Resu is repo ed ND w n it i e t a ore to MD <br /> ND Analyte was not detected or was less than the detection limit. <br /> NR Not Reported. See Report Comments. <br /> RDLO Reporting Detection Limit <br /> TI� Tentatively Identified Compounds <br /> Analytical Results Report A A�� <br /> 3 Lu 3 Anal al,LLC <br />