Appendix E.1:Data Usability Summary <br /> results for the two PAHs were either non-detect or greater than 10 times the amounts <br /> detected in the blank, so no flags were applied. <br /> • Naphthalene was detected in one method blank between the laboratory MDL and LOQ. <br /> Similar concentrations were detected in associated soil samples SB-38-S-42.5-081125 <br /> and SB-35-S-41.5-081124. The laboratory re-extracted the samples outside the holding <br /> time and naphthalene was not detected in the re-extracted method blank. The results <br /> were similar between the two sets of extractions. No data were qualified for the method <br /> blank detection because the second extraction confirmed the first set of results, and the <br /> data reported was not biased by the contamination. <br /> • Phenanthrene was detected between the laboratory MDL and LOQ in the method blank <br /> associated with groundwater sample SB-35-W-34-081124. Phenanthrene was detected in <br /> the sample at a concentration within 5 times the concentration detected in the method <br /> blank. The result was qualified E because the concentrations were similar, and the <br /> sample result may be biased by contamination. <br /> • Potassium was detected in the method blank associated with groundwater sample SB-36- <br /> W-35-081124. The associated sample result was not qualified because the concentration <br /> was above 10 times the amount detected in the method blank. <br /> Field QC Results <br /> Six equipment rinsate blanks, two field blanks, and nine trip blanks were submitted with the <br /> samples. No target compounds were detected in any of the trip blank samples. The equipment <br /> rinsate blanks and field blanks were free of contamination with the following exceptions: <br /> • The following target analytes were detected in equipment rinsate QA_Screen-R-080814: <br /> TPHd(61 gg/L), naphthalene (0.12 gg/L), fluorene (0.012 gg/L), phenanthrene <br /> (0.016 gg/L), benzo(a)pyrene (0.0035 gg/L), and dibenz(a,h)anthracene (0.0074 gg/L). <br /> Naphthalene was qualified E in associated groundwater sample SB-22-W-080813 and <br /> field duplicate SB-22-WD-080813. The other analytes were either non-detect or detected <br /> at concentrations greater than 10 times the amounts detected in the equipment rinsate, and <br /> no other data were qualified. <br /> • Naphthalene was detected above the program reporting limits in QA-Rinsate_Blank-R- <br /> 080815, QA-Screen-R-081121, and QA-Screen-R-090305. The compound was also <br /> detected within 10 times the concentration in associated groundwater samples SB-26-W- <br /> 82-080815, SB-33-W-36-081121, SB-42-W-090305, and SB-42-WD-090305. The <br /> results in the groundwater samples were qualified E for potential bias from <br /> contamination. <br /> COC Forms <br /> Sample analytical results were evaluated for agreement with the COC form. The evaluation <br /> determined that all samples were received at the laboratory in the appropriate containers and in <br /> good condition with the chain-of-custody form filled out properly. Several COC forms were <br /> submitted with incorrect analyses for trip blanks; however; the laboratory correctly analyzed the <br /> required analyses. <br /> E.1-6 <br /> From Science to Solutions <br />