' Data Usability Summary Page 3 of 4 <br /> Representativeness <br /> Representativeness was assessed through the evaluation of method blank samples,trip and equipment <br /> blank samples,chain-of-custody forms,preservation,and holding times. <br /> ' Method Blank Results <br /> TPHd were detected at 34 micrograms per liter(pg/L),below the laboratory LOQ of 100 pg/L, in the <br /> method blank associated with sample MW-5-W-070124. TPHd were detected at 150 pg/L in sample <br /> MW-5-W-070124. Concentrations that are within five times the amount detected in an associated method <br /> blank are likely biased by contamination introduced due the handling or analysis of the sample. In this <br /> case,the result in the field sample was within five times the amount detected in the method; however, <br /> because TPHd were detected above the laboratory LOQ, the historical data was evaluated to determine <br /> whether the result is representative of field conditions. TPHd were detected below the laboratory LOQ at <br /> 72 pg/L in the last sample collected at MW-5 in May 2006. This indicates the current result of 150 pg/L <br /> ' may be biased high from contamination introduced during the analysis. The result for TPHd in sample <br /> MW-5-W-070124 was qualified E to indicate the result may be biased. <br /> ' Field QC Results <br /> One equipment rinsate blank,QA-R-070124,was submitted with the samples. Naphthalene was detected <br /> at 0.056 pg/L, which is above the laboratory LOQ of 0.05 pg/L. Naphthalene was detected in the <br /> ' associated field sample,MW-5-W-070124, at 0.064 pg/L. Target anlayte detected in equipment rinsate <br /> blanks may indicate that the sample was contaminated during sample collection,handling, and/or <br /> analysis. The naphthalene result in MW-5-W-070124 was qualified E because this review could not <br /> ' determine if the result was representative of field conditions. Data collected at this location during future <br /> monitoring events will be used to determine representativeness. <br /> Chain-Of-Custody Forms <br /> ' Sample analytical results were evaluated for agreement with the chain-of-custody form. Based on the <br /> evaluation,all samples were received at the lab in the appropriate containers and in good condition with <br /> ' the chain-of-custody form filled out properly. <br /> Preservation and Holding Times <br /> Samples were preserved in the field as appropriate,were received at the laboratory within the acceptance <br /> ' temperature criterion of 4+2 °C. The samples were prepared and analyzed within specified holding <br /> times. <br /> Reporting Limits <br /> Data reported for this sampling event were reported with the laboratory MDLs. The MDL represents the <br /> lowest concentration point where an analyte can be positively identified,but the quantitation is an <br /> estimate. The LOQ is the lowest concentration of an analyte in a sample that the laboratory can report <br /> ' with precision and accuracy. Analytes that were reported between the MDL and LOQ for this data set <br /> were qualified J as estimates. <br /> ' Laboratory Fuel Notes for TPHd Analysis <br /> The laboratory noted that the observed hydrocarbon fuel pattern for TPHd analysis in sample MW-5-W- <br /> 070124 is not typical of#2 fuet/diesel. The reported result is due to groupings of peaks eluting in the <br /> ' DRO range. The sample was also silica-gel cleaned prior to the analysis and TPHd were not detected <br /> after the silica-gel cleanup. This indicates the TPHd results could be biased high due to biogenic material <br /> that was removed during silica-gel analysis. Data were not qualified for the TPHd fuel pattern note. <br /> t <br /> -=yO s CC <br /> aJr7/%o�' <br /> From Science to Solutions <br />