My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_SECOND 2008 SEMI-ANNUAL GROUNDWATER MONITORING AND SAMPLING REPORT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WELTY
>
35500
>
2900 - Site Mitigation Program
>
PR0508043
>
ARCHIVED REPORTS_SECOND 2008 SEMI-ANNUAL GROUNDWATER MONITORING AND SAMPLING REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2020 1:39:02 AM
Creation date
6/23/2020 3:38:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
SECOND 2008 SEMI-ANNUAL GROUNDWATER MONITORING AND SAMPLING REPORT
RECORD_ID
PR0508043
PE
2960
FACILITY_ID
FA0007905
FACILITY_NAME
CHEVRON PIPELINES
STREET_NUMBER
35500
STREET_NAME
WELTY
STREET_TYPE
RD
City
VERNALIS
Zip
95385
APN
25526003
CURRENT_STATUS
01
SITE_LOCATION
35500 WELTY RD
P_LOCATION
99
QC Status
Approved
Scanner
LSauers
标签
EHD - Public
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Data Usability Summary <br /> DATA QC OBJECTIVES <br /> SAIC evaluated project analytical data according to the following parameters in order to determine their <br /> usability: <br /> 1 • Precision <br /> • Accuracy <br /> • Representativeness <br /> • Completeness <br /> • Comparability <br /> DATA USABILITY SUMMARY <br /> The following sections summarize the findings of the data evaluation process. The following is a <br /> summary of the data verification and validation qualifiers used in the data evaluation: <br /> ualifier Description <br /> ' E Indicates the reported value is estimated due to associated QC results. <br /> J Indicates the reported value is an estimated concentration detected <br /> between the method detection limit(MDL) and limit of quantitation <br /> ' (LOQ). <br /> A summary of qualified data is provided in Table B-1. Data validation reason codes for all qualified data <br /> are also presented and defined on Table B-1. <br /> Precision and Accuracy <br /> The precision and accuracy of field and laboratory QC samples were evaluated. The calculated relative <br /> ' percent differences(RPDs)for field duplicate and MS/MSD pairs provided information on the precision <br /> of sampling and analytical procedures, and the RPDs for laboratory control sample/laboratory control <br /> sample duplicate(LCS/LCSD)pairs provided information on the precision of the analytical procedures. <br /> Evaluation of the percent recoveries (%Rs)of MS/MSDs,LCS/LCSDs, and surrogates provided <br /> information on accuracy. <br /> MS/MSDs <br /> ' Project-specific MS/MSDs were collected with the groundwater samples. All MS/MSD samples were <br /> with QC range with the following exceptions: The MS/MSD pair MW-5-WD-080717MS and MW-5- <br /> WD-080717MSD had TPH-DRO (C10-C25) percent recovery and RPD were outside the acceptance <br /> criteria. All associated samples MW-2-W-080717,MW-3-W-080717 and MW-5-W-080717 were <br /> flagged `E'. The MSD sample MW-6-W-080409MSD had Benzo(k)fluoranthene above the acceptance <br /> criteria however none of the associated samples had detections of this analyte so no flags were applied. <br /> When non project specific MS/MSD pairs were analyzed for QC proposes those samples were not <br /> evaluated in relation with matrix compliance in our samples. <br /> LCS/LCSDs <br /> A LCS was analyzed with each analytical batch of samples. All LCS/LCSD%Rs were within the <br /> laboratory control limits.The LCS analyzed with samples MW-2-W-080717,MW-3-W-080717, MW-5- <br /> W-080717 MW-5-WD-080717MS and MW-5-WD-080717MSD surrogate was above the QC criteria but <br /> its percent recovery was within acceptance range no flags were applied for this discrepancy. The <br /> LCS/LCD associated with samples QA-Pump-R-080409,MW-6-W-080409 and MW-7-W-080409 had <br /> Indeno (1,2,3-cd)pyrene and benzo(g,h,i)perylene below the QC limits. The samples were re-extracted <br /> and analyzed outside of the holding times with acceptable QC results and the data was comparable to the <br />
The URL can be used to link to this page
Your browser does not support the video tag.