My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4733
>
2300 - Underground Storage Tank Program
>
PR0232510
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:15 PM
Creation date
6/23/2020 4:29:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232510
PE
2361
FACILITY_ID
FA0003924
FACILITY_NAME
HUNT & SONS INC - ARCH ROAD CARDLOCK
STREET_NUMBER
4733
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95206
APN
17930008
CURRENT_STATUS
01
SITE_LOCATION
4733 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> SAN JOAQUIN Environmental Health Department <br /> C 00INITY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> ER Vine Stockton (209) 537-0723 June 24, 2020 <br /> Facility Address: I CERS ID: <br /> 4733 S HWY 99 , STOCKTON , CA 95206 10399867 <br /> Inspection Contact: Title: Phone: <br /> Jason Risen Environmental Contact (209) 537-0723 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br /> Consent For: I consent Olven By: <br /> p Inspection 0 Photos O Samples Mike Flores, Technician <br /> Service Technician Onsite: Exp, Date: Designated Operator: Exp. Date: <br /> Jerry Langrell 07/19/2020 Jerry Langrell 06/26/2021 <br /> Service Technician Manufacturer's Training <br /> VR, 11/20121 ; VMI , 08/13/21 ; OPW, 08/20/20 <br /> CGR = Tide 23 Carfornia Code of Regulations HSC = Health and a elY e CFR = Code 6f FederalegU a Ions <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284; CCR Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees a V ❑ R ❑ COS <br /> 2711 (d) <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V ❑ R o COS <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents ❑ V ❑ R ❑ COS <br /> 104 CCR 2711 UST operating permit application for facility and tank Information not submitted or current ❑ V ❑ R ❑ COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan ❑ V ❑ R a COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2)5 Failed to have an approved UST response plan n V ❑ R o COS <br /> 2634(e) <br /> 107 CCR 2632(d), 2641 (h), Plot plan/site map not submitted or failed to completely show Where monitoring is performed ❑ V ❑ R ❑ COS <br /> 2711 (a) <br /> 108 CCR 26375 2638(e), Failed to notify the EHD 48 hours prior to conducting testing a V DR ❑ COS <br /> 2643(g) <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months ❑ V ❑ R ❑ COS <br /> 110 CCR 2637(e), 2637(f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test ❑ V DR ❑ COS <br /> 111 CCR 26383 2641 Q), Failed to test monitoring and leak detection equipment every 12 months ❑ V ❑ R o COS <br /> 2715(f) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance o V DR ❑ COS <br /> 113 CCR 2638(c)5 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test a V ❑ R ❑ COS <br /> 114 CCR 2636(0(3), 2643(c) No 0. 1 gph annual line integrity test for pressurized piping, or within 30 days after repair ❑ V ❑ R ❑ COS <br /> (3) <br /> 115 CCR 2715(a)(1)(B), "Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days o V ❑ R o COS <br /> 2715(a)(3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification ❑ V DR ❑ COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining, recordkeeping, and inspection requirements ❑ V DR ❑ COS <br /> 118 CCR 2715(a)(1 )(A), Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" o V DR ❑ COS <br /> 2715(a)(2) <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented _ ❑ V DR ❑ COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of InstallalionlModificalion ❑ V ❑ R ❑ COS <br /> 121 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report ❑ V ❑ R ❑ COS <br /> 122 CCR 2631 , 2640.1 , Failure to submit and/or maintain documentation regarding compatibility for UST system components ❑ V DR ❑ COS <br /> 2665, 2711 <br /> FA0003924 PR0232510 Scoot 06/24/2020 <br /> EHD 23-01 Rev. 9/20/2019 Pagel of Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.