Laserfiche WebLink
E <br />MIKE SMITH ENGINEERING <br />4 NORTH MAIN STREET, LODI, CA 95240 (209) 334-2332 <br />n by: <br />Mike <br />11 <br />JOB #: 11221 <br />SHEET I of Z; <br />Date: 12-17-11 Checked by: Date: <br />Date: 2nd Revision: Date: <br />r <br />MIKE SMITH <br />E N I Nz E E R I N 0" C'C'" 590 <br />TANK ASSESSMENT FOR: <br />t <br />Tracy Unified School Dis <br />Proj. Location: 1975 W. Lowell Ave., Tracy, CA <br />A. Codes: CBC 2010ED. Seismic Category D -Wind Exposure C <br />Wind Speed 85 mph ASCE/SEI 7-05 AISCM -13th ED. <br />AITCM - 3rd ED. ACI 318-05 <br />B. Wood: 6x Members Use DF#1 4x Members Use DF#1 <br />2x Members Use DF#2 Studs Use Construction Grade <br />Glu -Lam Beams Use (24F -V4) <br />C. Steel: Structural Steel, ASTM A992, Fy = 50 ksi <br />Structural Tubing, ASTM A500, Fy = 46 ksi <br />Pipes, ASTM A501, Fy = 36 ksi <br />Cold Formed, ASTM A -924/A-792 or A-570, Fy = 50 ksi <br />Nuts and Bolts, use ASTM -A307 <br />D. Concrete: Foundations, fc = 2500 psi Columns, fc = 3000 psi <br />Walls, fc = 3000 psi <br />E. CMU Block: ASTM C-90 Grade N., fm = 1500 psi, Mortar Type S <br />Grout @28 Days fc = 2000 psi <br />F. Reinforcing: ASTM - 615: #4 and Smaller Grade 40, #5 and Larger Grade 60 <br />G. Solis Data: Report by CBC Table 1804.2 <br />Allowable Soil Bearing Pressure = 1.5 ksf <br />