My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5110
>
2200 - Hazardous Waste Program
>
PR0517868
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2024 4:36:49 PM
Creation date
6/23/2020 6:32:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0517868
PE
2227
FACILITY_ID
FA0005677
FACILITY_NAME
Sears #1288/6791
STREET_NUMBER
5110
STREET_NAME
PACIFIC
STREET_TYPE
Ave
City
Stockton
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
5110 Pacific Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2227_PR0517868_5110 PACIFIC_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
X 0 0 <br />9400 Ward Parkway <br />Kansas City, Missouri 64114-3319 <br />Tel. 816 333-9400 <br />fax: 816 333-3690 <br />http://www.burnsmcd.com <br />April 13, 2009 <br />Mr. Michael Olsen <br />Sears Holdings Corporation <br />3333 Beverly Road, 135-362A <br />Hoffman Estates, Illinois 60179 <br />Assessment Report & Certification <br />Waste Oil Storage Tank Installation <br />Sears Automotive Center #6791 <br />5110 Pacific Avenue <br />Stockton, California 95207 <br />BMcD Project: 51440 <br />Dear Mr. Olsen: <br />RE� E�1/ED <br />APR 2 3 2009 <br />ENVIRONMENT HEALTH <br />PERMITISERVICES <br />Burns & McDonnell has been asked to perform an independent assessment of the used oil <br />storage tank at the above facility in accordance with Title 22 CCR 66265.192(h)(1). The <br />tank is a 500 -gallon steel tank located in the automotive service area and labeled "USED <br />OIL ONLY." Afforda-Test was contracted to perform the on-site inspection and testing. <br />Their report is included as Attachment 1 (Report dated 01-26-09). A summary of our <br />assessment is as follows: <br />Title 22 CCR 66265.192(k) Assessment Considerations <br />(1) The rated capacity of the tank is 500 gallons and is fabricated from 10 gauge <br />carbon steel. A diagram of the tank is included as Attachment 2. <br />(2) The tank is a double-wall carbon steel vertical -cylindrical tank 48 inches in <br />diameter and 65 inches tall and is model No. A60341 as manufactured by Dunn <br />Industries, Inc. The tank is supported from a concrete floor slab which is more <br />that adequate to support a fully loaded tank. The tank is secured to the floor with <br />steel bolts to assist in resisting seismic forces or the unlikely event of floatation <br />due to high water. The space is heated and is not susceptible to frost heave. <br />(3) The tank is approximately 2 to 3 years old. <br />(4) There is no leak detection equipment installed. The facility conducts daily visual <br />inspections of the tank for evidence of leaks. <br />(5) There is no corrosion protection equipment or devices installed. The painted <br />surfaces have no corrosion on the carbon steel. <br />(6) The tank is located inside the building and a trench drain that drains to an oil <br />water separator prevents any spills from leaving the premises. <br />(7) The tank is a double-wall tank. The facility relies on visual inspections of the <br />area around the tank and through the open grating above the trench drain. <br />(8) Piping and hoses are visually inspected daily by facility personnel and therefore <br />meets the requirements of 22 CCR 66265.1920)(1) through 0)(3) and <br />66265.193(f). <br />(9) There is a fill level gauge on the tank and pressured piping connected to the tank <br />is equipped with an automatic air shut off valve to prevent overfill pursuant to <br />the requirements under 22 CCR 66265.193(f)(4). <br />
The URL can be used to link to this page
Your browser does not support the video tag.