Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM ( <br /> ONSITE TIERED PERMrrTWG ': ^, 20,4 <br /> CONDITIONALLY AUTHORIZED (CA) PAGE ENVIRONMENTA <br /> WASTE AND TREATMENT PROCESS COMBINATIONS }� <br /> EATH <br /> One a treatment nt unit R a 1 <br /> 606. 1. <br /> UNIT ID# C 1 Facility ID# Page of <br /> 629. <br /> Aqueous wastes,hazardous solely due to inorganic constituents,except asbestos,listed in Title 22,CCR,Section 66261.24(a)(1)(B)or(a)(2)(A)and which contain less than <br /> 1,400 ppm total of these constituents. (There is no volume limit for this wastestream.) Treatment using: <br /> (�a. Phase separation,including precipitation,by filtration,centrifugation,or gravity settling,including the use of demulsifiers and flocculants. <br /> (]b. Ion exchange,including metallic replacement. <br /> ❑c. Reverse osmosis. <br /> ❑d. Adsorption. <br /> ®e. pH adjustment of aqueous waste with a pH of between 2.0 and 12.5. <br /> [�E Electrowinning of solutions,unless those solutions contain hydrochloric acid. <br /> ❑g. Reduction of solutions hazardous solely due to hexavalent chromium,to trivalent chromium with sodium bisulfite,sodium metabisulfite,sodium thiosulfate,ferrous chloride, <br /> ferrous sulfate,ferrous sulfide,or sulfur dioxide. The solution contains less than 750 ppm of hexavalent chromium. <br /> 2. Aqueous wastes,hazardous solely due to organic constituents listed in Title 22,CCR,Section 66261.24(a)(1)(B)or(2)(B)and which contain less than 750 ppm total of these <br /> constituents. (There is no volume Ihnit for this wastestream.) Treatment using: <br /> ❑a. Phase separation by filtration,centrifugation,or gravity settling,but excluding super critical fluid extraction. <br /> ❑b. Adsorption. <br /> 3. Sludges resulting from wastewater treatment,dusts,solid metal objects,and metal workings which are hazardous solely due to the presence of constituents,except asbestos, <br /> listed in Title 22,CCR,Section 66261.24(axl)(B)or(a)(2)(A)and which,for dusts only,contain las than 750 plan total of these constituents. The monthly volume treated in <br /> this unit docs not exceed 5,000 gallons or 45,000 pounds. Treatment using: <br /> ❑a. Physical processes which constitute treatment only because they change the physical properties of the waste,such as filtration,centrifugation,gravity settling,grinding,shredding, <br /> crashing,or compacting. <br /> ❑b. Drying to remove water. <br /> ❑c. Separation based on differences in physical properties,such a size,magnetism,or density. <br /> 4. Alum,gypsum,time,sulfur,or phosphate sludges. The monthly volume treated in this unit does not exceed 5,000 gallons or 45,000 pounds. Treatment using: <br /> ❑a. Drying to remove water. ❑b. Phase separation by filtration,centrifugation,or gravity settling. <br /> 5. Special wastes listed in Title 22,CCR,Section 66261.120 that meet the criteria in Title 22,CCR,Section 66261.122 which is hazardous solely due to the constituents,except <br /> asbestos,listed in Title 22,CCR,Section 66261.24(a)(1)(B)or(a)(2)(A)and which contain las than 750 ppm total of these constituents. The monthly volume treated in this <br /> unit does not exceed 5,000 gallons or 45,000 pounds. Treatment using: <br /> ❑a. Drying to remove water. <br /> ❑b. Phase separation by filtration,centrifugation,or gravity settling. <br /> ❑c. Screening to separate components based on size. <br /> ❑d. Separation based on differences in physical properties,such as size,magnetism,or density. <br /> 6. Special wastes classified under Titre 22,CCR,Section 66261.124 as special wastes,except asbestos,which is hazardous solely due to the constituents,except asbestos,listed in <br /> Title 22,CCR,Section 66261.24(a)(1)(B)or(a)(2)(A)and which contain less than 750 ppm total of these constituents. The monthly volume treated in this unit does not exceed <br /> 5,000 gallons or 45,000 pounds. Treatment using: <br /> ❑a. Drying to remove water. ❑c. Magnetic separation. <br /> ❑b. Phase separation by filtration,centrifugation,or gravity settling. <br /> 7. Sofas contaminated with acetals listed in Title 22,CCR,Section 66261.24(a)(2)(A). The monthly volume treated in this unit does not exceed 5,000 gallons or 45,000 pounds. <br /> Treatment using: <br /> ❑a. Screening to separate components based on size. ❑b. Magnetic separation. <br /> Oil mixed with water and o0lwater separation sludges. (There is no volume limit for this wastestream.) Treatment using: (NOTE: Some used oil/water separation is allowed <br /> under the CEL category.) <br /> ®a. Phase separation by filtration,centrifugation,or gravity settling,but excluding super critical fluid extraction,including the use of demulsifiers and flocculants. Heat can be used,but <br /> must not exceed 160 degrees Fahrenheit. <br /> ®b. Separation based on differences in physical properties,such a size,magnetism,or density. <br /> ❑c. Reverse osmosis. <br /> 9. Neutralization of acidic or alkaline wastes,hazardous solely due to corrosivity,or toxic only from the acid or caustic material,in elementary neutralization units. (There is no <br /> volume limit for this wastestream.) <br /> ®a. The waste contains less than 10 percent acid or base constituents by weight. There is no volume limit for this category. <br /> (]b. The waste contains 10 percent or more acid or base constituents by weight and is treated in batches that do not exceed 500 gallons atone time. <br /> 10. Not in use/exempted—formerly recovery of silver from photofinishing. <br /> 11. Not in use/sunsetted—formerly treatment of spent cleaners and conditioners which are hazardous solely due to copper or copper compounds. Treatment of this wastestream <br /> Is no longer allowed wider Conditional Authorization as of January 1,1998. Treatment of this wastestream now requires authorization under either Permit by Rule or,tribe <br /> total volume treated is less than 55 gallons per month,corder Conditionally Exempt Small Quantity Treatment. <br /> 12. A waste stream technology combination certified by the Department pursuant to Section 25200.1.5 of the Health and Safety Code as appropriate for authorization under <br /> Conditional Authorization <br /> ❑ Certified Technology Number: <br /> UPCF hwfca(1/99)-1/2 www.unidocs.org Rev.05/08/00 <br />