My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1190
>
2300 - Underground Storage Tank Program
>
PR0528518
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 3:06:04 PM
Creation date
6/23/2020 6:37:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528518
PE
2332
FACILITY_ID
FA0019193
FACILITY_NAME
SANBORN CHEVROLET PROLUBE SHOP
STREET_NUMBER
1190
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728012
CURRENT_STATUS
02
SITE_LOCATION
1190 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0528518_1190 S CHEROKEE_.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (One form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections 1.A 111,1V,and IX below) 430. <br /> ❑ 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> 6.TEMPORARY UST CLOSURE 7.UST PERMANENT CLOSURE ON SITE 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430& 1 DATE EXISTING UST DISCOVERED: 430b. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ _ f 1 <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3. <br /> BUSINESS SITE ADDRESS 103. CITY 104. <br /> Ilio S. cjnevok lei & i <br /> II. TANK DESCRIPTION <br /> TANK ID# 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> ❑ 1.A STAND-ALONE TANK Complete one page for each <br /> / ❑ 2.ONE IN A COMPARTMENTED UNIT compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS G. 436, NUMBER OF COMPARTMENTS IN THE UNIT 437. <br /> III. TANK USE AND CONTENTS <br /> TANK USE ❑ la.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Include Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439& <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ❑ Ib.PREMIUM UNLEADED 440. <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM(Specify): 440& <br /> NON-PETROLEUM: 7.USED OIL ❑ 10.ETHANOL <br /> 11.OTHER NON-PETROLEUM(Specify). 440b. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 95.UNKNOWN 443. <br /> PRIMARY CONTAINMENT ❑ L STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 444& <br /> SECONDARY CONTAINMENT ❑ 1.STEEL [13.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99,OTHER(Specify): 445& <br /> OVERFILL PREVENTION ❑ 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ I.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 99.OTHER _ 460. <br /> SYSTEM TYPE ❑ 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION 123 CCR§2636(a)(3)) 458. <br /> PRIMARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464. <br /> _❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464& <br /> SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ I0.RIGID PLASTIC 464b. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c. <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 46441. <br /> VENT SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): q4&T <br /> 641 <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): q466 <br /> l. <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): g64hj <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464t' <br /> RISER PRIMARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464J' <br /> 464'1. <br /> RISER SECONDARY CONTAINMENT ❑ I.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 46641. <br /> FILL COMPONENTS INSTALLED ❑ 1.SPILL BUCKET ❑ 3.STRIKER PLATEIBOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 45la-c. <br /> VII. UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469x. <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ❑ 469b.4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br /> accurate and in full compliance with legal requirements. <br /> APPLICANT SIGNATURE DATE 470' <br /> APPLICANT NAME(print) I' APPLICANT TITLE 472' <br /> UPCF UST-B Rev.(12/2007)-1/2 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.