Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. <br />A. General Information <br />Facility Name: Fremont Shell <br />Site Address: 2494 E. Fremont St. <br />Facility Contact Person: Michael Dominguez <br />Make/Model of Monitoring System: Veeder- Root TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br />City: Stockton <br />Bldg. No.: <br />Zip: 95205 <br />Contact Phone No.: 209 ) 941-8743 <br />Date of Testing/Servicing: 06 / 12 / 2006 <br />Tank ID: Gasoline - 87 <br />Tank ID: Gasoline - 91 <br />■ In -Tank Gauging Probe. <br />Model: 0847390-109 <br />■ In -Tank Gauging Probe. <br />Model: 0847390-109 <br />■ Annular Space or Vault Sensor. <br />Model: 0794380-302 <br />■ Annular Space or Vault Sensor. <br />Model: 0794380-302 <br />® Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />® Fill Sump Sensor(s). <br />Model: 0794380-208 <br />® Fill Sump Sensor(s). <br />Model: 0794380-208 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />■ Electronic Line Leak Detector. <br />Model: 848480-001 <br />® Electronic Line Leak Detector. <br />Model: 848480-001 <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />Other (specify equipment a and model in Section E on Page 2). <br />■ Other (specify a ui ment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment pe and model in Section E on Pae 2). <br />❑ Other (specia equipment a and model in Section E on P e 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />Shear Valve(s). <br />■Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). J <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />® Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />N Shear Valve(s). <br />Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and <br />Chain(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />°If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/seryiced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any eq u' t capable of eating such re orts, I have also <br />attached a copy of the report; (check all that apply): ® System set-up X I m history o <br />Technician Name (print): Bruce Stewart Signature: <br />Certification No.: A31131 <br />Testing Company Name: Walton Engineering, Inc. <br />License. No.: 617238 <br />Phone No j 916 ) 373-1152 <br />Site Address: 3900 Commerce Drive, West Sacramento, CA 95691 Date of Testing/Servicing: 06 / 23 / 2006 <br />UN -036 - 1/4 Page 1 of 3 Rev. 06/04/01 <br />CUPA: Environmental Health Department <br />INSPECTOR: Toua Yang <br />ALTON <br />"ENGINEERING, I . <br />www.unidoes.org <br />