<br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
<br /> 1868 E.Hazelton Ave. • Stockton,CA 95205-6232 •Phone(209)468-3420
<br /> Donna Heran,R.E.HS.,Director
<br /> ENVIRONMENTAL HEALTH
<br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY
<br /> PERMIT_ TO OPERATE
<br /> Program Permit Permit
<br /> Record ID Number Program Code and Description Valid
<br /> PR�5184 -- 1 SMAtt Q11ANTt-TY--M-
<br /> Hazardous Waste Generator Program:
<br /> In order to maintain the permit to operate, Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13,
<br /> Sec_25100 et seq and Title 22, rnla Code of Regulations Chap 20 ____-- --__ _
<br /> - -•-- - -•--• -
<br /> PR0231622 2300- NDERGROUND STORAGE TANK FACILITY 1!112013 To 12131!2013
<br /> Underground Storage Tank ram•
<br /> California Health and Safety ode iv.20,Chap.6.7 and'Title 23,California Code of Regulations,_Chap_16. ______________________
<br /> -------- •------ ----- ---- ---------------------------------------
<br /> P/E Tank Tank Record ID Permit# Ca aci Contents Permit Status System Type Leak Detection
<br /> 2352 8 390002316220520452 PT0022549 20,000 REGULAR UNLEADED Active,billable DOUBLE-WALL Continuous Interstitial Monitoring
<br /> 2350 9 390002316220520453 PT0022550 12,000 PREMIUM UNLEADED Active,billable DOUBLE-WALL Continuous Interstitial Monitoring
<br /> 2350 10 390002316220520454 PT0022551 8,000 DIESEL Active,billable DOUBLE-WALL Continuous Interstitial Monitoring
<br /> BOE 117#' 440`45.fE2 ,
<br /> Underground Storage Tank Permit Conditions
<br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions.
<br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions
<br /> established by San Joaquin County.
<br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both
<br /> the Tank Owner and tank Operator receive a copy of the permit.
<br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved
<br /> monitoring,response,and plot plans shall be maintained onsite with the permit.
<br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit.
<br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and
<br /> provide documentation of such servicing to this office.
<br /> 7) In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan.
<br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was
<br /> performed.
<br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change.
<br /> 10) Upon,any change in equipment,design or operation of the UST system(including change in tank contents or usage),.the Permit to Operate will be subject to review,modification or
<br /> revocation.
<br /> 11) Construction,repair and/or removal pemtits are required from the EHD prior to any change,repair or removal of UST system equipment.
<br /> 12) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency.
<br /> 13) A"Conditional'Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated.
<br /> — ------------ -------•----
<br /> PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause.
<br /> PERMIT(s)Valid only for: TESORO REFINING Sr MARKETING CO
<br /> Tank Owner: , TESORO SIERRA PROPERTIES
<br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES
<br /> TESORO/SHELL 68150" Facility ID FA0000055
<br /> Regulated Facility: 13975 E HWY 88 AccountiD AR0000054
<br /> LOCKEFORD CA 95237 Issued 2/1912013
<br /> Billing Address: LISA GARCIA, MS TX1-022
<br /> TESORO REFINING & MARKETING CO
<br /> 19100 RIDGEWOOD PKWY
<br /> SAN ANTONIO TX 78259
<br /> 7023.rpt
<br />
|