My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_1989-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2022 2:55:50 PM
Creation date
6/23/2020 6:37:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2001
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231952_2905 W BENJAMIN HOLT_1989-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
490
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications Standard del Is <br /> Operating Temp.: -250 to+1 30OPW Form No. qW Description AP <br /> Compatible fuels: Unleaded gasoline 848480-001 Pressurized Line Leak Detector for F.E.Petro Pumps* <br /> Leaded gasoline 848480-002 Pressurized Line Leak Detector with in-line check valve <br /> 5%methanol/95%unleaded for Red Jacket and Tokheim Pumps(includes line leak <br /> 10%ethanl/90%unleaded um sensor,in-line check valve,and <br /> 15%MTBE/85%unleaded pump port strainer) <br /> Diesel 848480-003 Pressurized Line Leak Detector with SwiftCheckTM for <br /> Kerosene Red Jacket and Tokheim Pumps(includes line leak <br /> Jet Fuel sensor and SwiftCheckTM check valve) <br /> Aviation gasoline `Requires an F.E.Petro Precision Check Valve,F.E.Petro Part Number <br /> Line flow rate: 120 gpm.max. 400153925. Veeder-Root check valve not required. <br /> Design: intrinsically safe Console Compatibility <br /> Operating Range: 0-50 psi. TLS-3508 Consoles** Series 8482 <br /> Proof Pressure: 200 psi TLS-350 Consoles Series 8470 <br /> '*Pressurized Line Leak Interface Module,Form No.330373-001,and Pressurized <br /> Gi rte t1 Line Leak Controller Module,Form No.330374-001,required for use of PLLD with <br /> PLLD TLS-35OR or TLS-350 consoles.A software enhancement module is also available <br /> Red Jacket: P33R1 (1/3 HP) to enable 0.1 gph leak detection for PLLD. <br /> P75S1 (3/4 HP) <br /> PLLD Supported Applications <br /> P150SI(1-1/2 HP) Supported Piping: 2"Fiberglass-350' <br /> F.E.Petro: STPR 33(1/3 HP)* 3"Fiberglass-150' <br /> STPR 75(3/4 HP)* 2"Steel-440' <br /> STPR 150(1-1/2 HP)* 1-112 Enviroflex-400' <br /> Tokheim and Bennett: 23 psi ouput minimum Supported Applications: Siphon/Manifolded-Tanks(Two Tanks- <br /> Red Jacket Big Flo: P3001-13-21-18(3 HP)Only One Pump) <br /> Manifolded Lines(Two Tanks-Two <br /> FE Petro High Capacity: STP3(3 HP)Only <br /> Pumps Into Common Line) <br /> *"R"designates precision check valve Electronic Blenders <br /> Contact Veeder-Root for approved piping systems <br /> No Mechanical Blenders <br /> SwiftCheckTM Tkpical Installations <br /> The SwiftCheck TNI valve installs into the 2"leak detector port on the Red from the check valve,install a 2"tee,and mount the Veeder-Root line. <br /> Jacket or Tokheim submersible pump.The Veeder-Root line leak sensor leak probe into the tee. <br /> is then screwed into the SwiftCheckTIA valve. Disable the pump's functional element by removing its spring and piston. <br /> Disable the pump's functional element by removing its spring and piston. Pressurized Line Leak Detector Installation Cable <br /> In-Line Check Valve Veeder-Root offers direct burial cable(Form No.838100-xxx)for <br /> The in-line check valve is threaded at both ends for a 2"NPT fitting and locations where conduit does not exist.See price list for ordering <br /> should be installed into the submersible pump discharge.Downstream information. <br /> SwiftCheckTM Installation Diagram In-Line Check Valve Installation diagram <br /> y <br /> LINE LEAK LINE LEAK SENSOR <br /> SENSOR <br /> VENT SCREW <br /> AIFTCHECK <br /> V <br /> ® I VALVE <br /> I <br /> 1_�_1 2'PIPE TEE <br /> Z IN-LINE CHECK VALVE <br /> ® Environmental Products <br /> The Leader in Tank Monitoring Technology <br /> 125 Powder Forest Drive,Post Office Box 2003,Simsbury,CT 06070-2003 TEL:(860)651-2700.FAX:(860)651-2719 TECH SUPPORT:(860)651-2753 <br /> BRAZIL:Sao Patio-CANADA:Mississauga.Ontario - ENGLAND Richmond Surrey-FRANCE.Rungis Cedex-GERMANY:Ne,:,ausen/Elder-SINGAPORE'.Singapore <br /> p(in(c <br /> 13292 Replaces 13180 P 577013-071 AR9 �?;a 95 <br />