Laserfiche WebLink
0 'r a,"^ ^v <br /> STATE OF CALIFORNIA ." <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM Bao <br /> 0 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ® 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CL ON SI <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOV J� <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: ('��:p. q Z7 <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.III B. MANUFACTURED BY: .f1S <br /> C. DATE INSTALLED(MO/DAYNEAR) I q�, D. TANK CAPACITY IN GALLONS: (Z 000 <br /> ILTANKCONTENTS IFA•1ISMARKED.COMPLETE ITEM C. <br /> 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. I C. <br /> © laREGULUNLEADR 6 AVIATION GAS <br /> ❑ 3 DIESEL ❑ <br /> A. <br /> 2 PETROLEUM ❑ 80 EMPTY a 1 PRODUCT ❑ lb PREMIUM ❑ 4 GASAHOL ❑ 7 METHANOL <br /> UNLEADED ❑ 5 JET FUEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF I 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL 0 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100"/ METHANOL? YES NO_ <br /> D.CORROSION U 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAPXl 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) _ OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) I _ <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROU_NOOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE SUCTION A,16-,? PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION U 1 SINGLE WALL A 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)Alto 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ® 3 idONERSTI IAITOR ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ® 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING 0 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING X 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN u 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NO i❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY RJURY, D O T F MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> (PRINTED d SIGNATURE) f <br /> II1 —. .lb SAN <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OFTH FOUR UMBERS q�LOWvi <br /> ' <br /> COUNTY# JURISDICTION# I FA ITY#003 If TANK# <br /> STATE LD.# - i d a I �►� <br /> PERMIT NUMBER fPERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> z d G/b <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILECIf <br /> FILE THIS FORM WITH TWOCAL AGENCY IMPLEMENTING THE UNDERGROUND STO�E TANK REGULATIONS <br /> FORM B (12-91) <br /> ro��5 n FOR00948 R6 <br />