My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
minE <br /> Figure D9-3 6. Wait at least 30 minutes, if the water level in the <br /> Air Supply Air Supply collar does not drop more than W,the tank is <br /> Valve closed considered acceptable and leak free. <br /> VenReservoir 7. If the level drops more than the W, ensure that inlet <br /> and outlet pipe caps or plugs and collars are not <br /> leaking,then refill the tank and retest. <br /> 8. After the tank is proven to be watertight, remove the <br /> water in the tank to below the pipe invert. <br /> psigJ�►pslg p g 9. For additional testing instructions for a Non <br /> Petroleum tank, refer to Supplemental Documents <br /> (Section R). <br /> 16. With all compartments under pressure, cover <br /> fittings and manway(s)with soap solution and • <br /> inspect. <br /> 17. After completing air test, release pressure. <br /> 18. Remove all gauges,valves, and hose assemblies. Do not enter the tank excavation unless in <br /> 19. Replace and tighten fitting plug(s). <br /> compliance with OSHA regulations. Follow OSHA <br /> 20. Replace the plastic vent plug in the open fittings. guidelines for tank excavation. <br /> Collapsing excavation walls can cause injury <br /> or death. <br /> • STABLE EXCAVATIONS <br /> ® ® When your excavation is in stable, undisturbed soil; <br /> use the minimum spacings <br /> (per Figure E-1 and Table E-2). <br /> If the tank is to be water tested,It must be supported <br /> by backfill on all sides to the top of the tank.Failure Figure E-1 <br /> to do so may result in tank damage. �/ <br /> ,\// B A A <br /> These instructions are for tanks that require a post N\ <br /> installation water test. �/ <br /> Perform the following in the order listed. �/ <br /> 1. Comply with the requirements of Section C. <br /> 2. Tanks may only be water tested if the backfill is at j <br /> tank top(see Figure D10-1). B B <br /> Fill 2"into Figure D10-1 /\\�� Stable Soil /\\�\/\\X\1 <br /> Access Colla <br /> TABLE E-2 <br /> ; \\j/\ 4',6',8'Diameter Tanks <br /> j\//j Minimum w/12"x 12"CSI Deadmen <br /> \\\/% Water <br /> %\/i% A 18"(457mm) 24"(610mm) <br /> ' Backfill :%\\//% (457mm) 24"(610mm) <br /> .......................... ...•..•.. ......... .........../\ij 10'Diameter Tanks <br /> Minimum w/18"x 8"CSI Deadmen <br /> 3. Expose tank penetrations on tank top by A 18"(457mm) 36"(914mm) <br /> temporarily removing backfill. B 24"(610mm) 24"(610mm) <br /> 4. So water does not exit the inlet/outlet pipe, install a 12'Diameter Tanks <br /> turned up elbow or plug. Minimum w/18"x8"CSI Deadmen <br /> 5. Completely fill the tank with water to a level 2" into A 24"(slomm) 36"(914mm) <br /> the access collar(s). B 24"(610mm) 24"(610mm) <br /> 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.