My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
When connecting the end of a hold-down strap to the • Refer to Table H-6 for minimum wire rope diameter <br /> anchor, common methods include: (see Figure H-4) and strength. <br /> • Drop-forged turnbuckle(A) <br /> TABLE H-6 <br /> • Looped wire rope(B) <br /> Wire Rope <br /> • Combination of both A and B (C) Tank Minimum Minimum <br /> • After hardware is installed, all exposed metal on Diameter Diameter Ultimate Strength <br /> the anchoring system must be protected against 4' 3/8'(lomm) 13,120 lbs(5,951 kg) <br /> corrosion. _ _ <br /> 6', 8', 10', 12' '/z"(13mm) 23,000 lbs(10,433 kg) <br /> Figure H-4 <br /> • Follow recommendations of the wire rope <br /> j manufacturer, as well as all industry standards when <br /> selecting, handling,attaching or connecting wire rope. <br /> • Tighten all hardware uniformly and follow the <br /> JA JBC manufacturer's torque specifications. Double check <br /> the tightness once the anchoring system is complete. <br /> • When forming a loop in the wire rope, a splice is <br /> required for connecting the two ends together. Use <br /> a minimum of four clamps for%"wire rope and a <br /> minimum of six clamps for'/"wire rope. Place the <br /> rope ends parallel to each other and install the clamps <br /> DROP-FORGED TURNBUCKLES as shown in Figure H-7. <br /> May be used in place of all or a portion of wire rope Figure H-7 <br /> described in this section. <br /> TABLE H-5 <br /> Tank Minimum Turnbuckle Diameter(by type) 3/8"Wire Rope/Clamp Alignment <br /> i Minimum � <br /> Dia. Hook Jaw ; Eye Working <br /> I Load Limit" <br /> 4' 1/2' 3/$' V 1,200 lbs 1/2"Wire Rope/Clamp Alignment <br /> 6' 3/a" '/2' '/z 2,200 lbs <br /> 8' 2%" '/a° 3/a° 5,200 lbs <br /> 10' 2%" '/a3/a' 5,200 lbs DEADMEN ANCHORS <br /> 12' 2%" W 3/a 5,200 lbs Deadmen are made of reinforced concrete, designed <br /> according to the American Concrete Institute(ACI)code, <br /> *ultimate load should be 5 times working load limit at least 12' long, placed end to end equal to tank length, <br /> and with at least two anchor points per deadman. <br /> WIRE ROPE • Refer back to Table A-5 for CSI deadmen <br /> dimensions and weight. <br /> • Each tank requires its own deadman on both sides, <br /> or if one deadman is used between adjacent tanks, <br /> Wire rope should never be in direct contact with any it must be doubled in width. <br /> portion of the tank or damage may occur. • A separate anchor point must be provided for each <br /> strap. <br /> • A method to use wire rope on the ribs over the tank ° CSI deadmen are engineered and sized to the tank <br /> top is available(see Supplemental Documents, ordered. <br /> Section R). <br /> • Use 6 x 19 Improved Plow Steel IWRC,or better,wire ° Placement of CSI deadmen is the same as standard <br /> rope. deadmen. <br /> • Lay the deadmen in the excavation parallel to the <br /> tank and outside of the tank shadow. <br /> (see Figure H-8). <br /> 17 <br />