My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB JUNE 2008 <br /> General Re uirements for all USTs <br /> , <br /> Required on all Required on all USTs. If tank system constructed Pre-July 1, <br /> • All USTs USTs. No manual override and meets one of the following 2003 <br /> shall be options: • SW UDC construction with <br /> resistant to • Minimum 5 gallon continuous monitoring. <br /> corrosion or capacity. • Device activates at 90%; restricts flow or CCR 2636(g)(C) <br /> have corrosion CCR 2635(b)(1)(B) triggers audible and visual alarm. (Devices such <br /> protection. as ATG OR Ball float/vent valve may be used to fulfill this • Testing required every three years. <br /> • Resistant to requirement.) CCR 2635(b)(2)(A) HSC 25284.1;CCR 2637 <br /> galvanic corrosion <br /> Device activates at 95%; restricts flow and If tank system constructed on or after <br /> OR • Method to remove OR activates audible alarm five minutes before July 1. 2003: <br /> liquid from the overfill. (Devices used in conjunction with each other <br /> • Components bucket. such as ball float/vent valves, ATG's, and external • Must be liquid and vapor tight. <br /> CCR 2635(b)(1)(C) audible and visual alarms may be used to fulfill this <br /> must be requirement.) CCR 2635(b)(2)(B) <br /> isolated from • For monitoring of UDC see <br /> the backfill, • Required to be ®R Device activates at 95%; provides positive "Monitoring of Double-walled Piping <br /> including tested annually. shutoff of flow to the tank. Installed Before July 1, 2004". <br /> turbines, (Devices such as drop tubes/flapper valves may be HSC 25290.2 <br /> risers, and spill HSC 25284.1,25284.2 used to fulfill this requirement.)CCR 2635(b)(2)(C) <br /> p Also See LG-166 <br /> buckets. • Device activates before fittings are exposed J tank system constructed on or after <br /> OR to product and provides positive shutoff. July 1, 2004: <br /> 40 CFR 280.31, 280.70; (Devices such as drop tube/flapper valves may be used <br /> CCR 2635(a)(2);2636(b), to fulfill this requirement.)CCR 2635(b)(2)(D) • Must be liquid and vapor tight. <br /> 2662(c) <br /> • Requirement may be waived by local agency if all of • Required construction depends on <br /> the following conditions are met: piping configuration. <br /> -Inlet exists in observable area. • For monitoring of UDC see <br /> -Spill container adequate to collect any overfill. "Monitoring of Double-walled Piping <br /> -Tank system filled by no more than 25 gallons at one Installed after July 1, 2004". <br /> time. <br /> CCR 2635(b)(3). Also see LG-150 HSC 25290.1 <br /> Page 2 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.